ESH-01 – Preliminary Audit of Electrostatic Hazards

Audit details

Instructions

Before starting the audit

This is an operational preliminary audit. It does not replace the required Explosion Risk Assessment (ERA), Explosion Protection Document (EPD), detailed technical audit or specialist electrostatic-hazard assessment. The audit checks whether electrostatic hazards have been identified within the assessed scope, whether protective measures relating to those hazards have been defined and are used in practice, and whether the documentation reflects the actual way the work is performed. Matters that cannot be resolved within this preliminary audit should be identified for further verification.

When is the audit useful?

The audit is particularly useful in areas involving activities that can generate or accumulate electrostatic charge, including transfer or pumping of liquids, handling of bulk solids, transport of materials or packages, and use of films, bags or other plastics.

The audit is also worth considering where the way the process is run or individual activities are performed differs from typical conditions, for example during periodic, irregular or non-routine work, activities requiring direct operator involvement, temporary changes to the configuration of installations or equipment, use of new or different-than-usual materials, as well as following technical, organisational or material changes and during work carried out by contractors or persons less familiar with the process.

The audit is also useful where applicable rules are unclear, team knowledge is inconsistent, an unusual event has occurred, or there are doubts about the effectiveness of controls, for example whether a particular item is properly earthed.

How should the audit be performed?

  • perform the audit as a team, involving persons who know the assessed process and the actual way the work is performed, in particular representatives of operations, maintenance and occupational safety / HSE;
  • base answers on documentation, field observation and discussions with persons performing or supervising the work;
  • answer only on the basis of what can be reliably confirmed — do not guess;
  • select YES where the available evidence confirms that the assessed condition is met;
  • select NO where the available evidence confirms that the assessed condition is not met;
  • select UNKNOWN where the available information does not allow a clear conclusion. UNKNOWN is a valid answer and does not automatically mean a nonconformity;
  • select NOT APPLICABLE only where the question allows that answer and it can be clearly justified that the assessed requirement does not apply;
  • for a NO answer, record what was found and the basis for the finding. Where practicable and safe, support the finding with a photograph or other evidence;
  • if the audit identifies a condition requiring immediate response, take appropriate action without waiting for the audit to be completed.

Additional questions may appear depending on the selected answers.

Guidance icons
Why do we ask this?Explains why the question matters.
Learn moreAdditional information, examples and materials.
How to interpret?How to understand the requirement and assess the answer.
What to check and what evidence to expect?Verification points and expected evidence.
For consultationMarks a question for additional consultation.

Preliminary applicability check

Determine whether this preliminary audit applies to the assessed process or area.

Qualification condition

Can a credible scenario be identified for the assessed process, area or activity in which both of the following may occur at the same time:
(1) an explosive atmosphere; and
(2) conditions that may lead to the generation, accumulation or discharge of electrostatic charges?

When determining applicability, consider all relevant process states and operating modes, in particular normal operation, start-up and shutdown, filling and emptying, cleaning, product or configuration changes, and other foreseeable activities that differ from typical operation. Foreseeable and rare malfunctions should also be considered where they may be relevant to the assessed hazard.

Select an answer to the qualification condition
Bulk solids
Liquids
Gas / vapour releases and two-phase flows
Large flat surfaces
Personnel
Maintenance
Other electrostatic mechanisms
P1

Explosion Risk Assessment (ERA)

Is there a current Explosion Risk Assessment (ERA) applicable to the assessed scope that addresses electrostatic hazards associated with the activities performed and the current way the work is carried out?

Sources for confirmation:📄 Documentation
Why do we ask this?

A current Explosion Risk Assessment (ERA) provides the documentary basis for the subsequent assessment of electrostatic hazards. If it is missing, outdated, does not cover the assessed scope or does not reflect the actual process conditions, conclusions reached later in the preliminary audit may be based on an inappropriate foundation.

Learn more

Explosion Risk Assessment (ERA)

An Explosion Risk Assessment should provide a comprehensive assessment of hazards associated with the possibility of an explosion. It should take into account, among other things, the likelihood and duration of the occurrence of an explosive atmosphere, the likelihood that ignition sources may occur and become active — including electrostatic discharges — as well as the substances and mixtures used, installations, process conditions, interactions between processes, and the possible consequences of an explosion.

In this preliminary audit, ERA refers to the documented explosion risk assessment applicable to the process or area being assessed, regardless of the title of the document in which it is recorded. The assessment may form part of the Explosion Protection Document (EPD), exist as a separate study, or be documented in other related explosion-safety records.

In this question, the main task is to confirm that the required assessment has actually been performed, is current, covers the assessed scope, reflects the present way the process is operated, and addresses hazards associated with static electricity. It is also useful to establish which version of the documentation is applicable, where it is available, and whether the way in which it is maintained and updated can be confirmed. The inability to identify a specific person responsible for the document should not, by itself, determine the answer to this question if the existence, scope and currency of the required assessment can otherwise be confirmed reliably.

After technical, material or organisational changes, check whether the scope and assumptions of the assessment still correspond to the actual process. Where start-up, shutdown, filling, emptying, cleaning, or foreseeable and rare malfunctions are also relevant to the assessed scope, check whether the corresponding process states are included in the assessment.

At this stage of the audit, do not yet determine in detail during which specific activities electrostatic charge is generated, accumulated or discharged, whether a possible discharge can constitute an effective ignition source, or which protective measures are required. These matters are verified in subsequent audit questions.

Significance of the Explosion Risk Assessment for the EPD

Under § 7(1) of the Polish Regulation of the Minister of Economy of 8 July 2010, before making a workplace available for use, the employer prepares an Explosion Protection Document (EPD) on the basis of the risk assessment referred to in § 4(4) and (5).

The EPD documents the results of the assessment and the explosion-safety arrangements arising from it. Under § 7(3), it should in particular include a description of the protective measures applied, a list of hazardous areas together with their zone classification, and the employer’s declaration including, among other things, confirmation that the risk assessment has been performed and the review intervals for the protective measures used.

A properly performed and current Explosion Risk Assessment therefore provides the basis for subsequent conclusions documented in the EPD. If the assessment does not reflect the actual process, omits significant hazards, or has not been updated following changes relevant to explosion safety, the reliability of the resulting conclusions concerning hazardous zones, ignition sources and protective measures also requires re-verification.

Employer responsibilities

Carrying out the risk assessment associated with the possible occurrence of an explosive atmosphere and preparing the Explosion Protection Document (EPD) on that basis are responsibilities of the employer. The assessment should cover, among other things, the possible occurrence of an explosive atmosphere and the occurrence and activation of ignition sources, including electrostatic discharges, as well as the installations used, substances and mixtures, processes, their interactions and the possible consequences of an explosion.

On the basis of the completed assessment, the employer prepares the EPD before making the workplace available for use. The document should reflect the results of the assessment and the resulting safety requirements, including, among other things, the protective measures applied, the classification of hazardous areas and the rules for their safe use.

The employer is also responsible for ensuring that workplaces, equipment and work organisation correspond to the conclusions arising from the risk assessment and the EPD, and that the documentation is updated when changes to the workplace, equipment or work organisation may affect explosion safety.

How to interpret?

Select YES only when a current and applicable Explosion Risk Assessment can be identified for the assessed scope and actual process conditions, and it can be confirmed that hazards associated with static electricity were considered in the assessment. Discussions with persons familiar with the process may help identify the relevant documentation and establish its scope and currency, but they do not replace a documented Explosion Risk Assessment.

NO is appropriate when it has been confirmed that the required Explosion Risk Assessment has not been performed, is outdated, does not cover the assessed scope or actual process conditions, or does not address electrostatic hazards where they require consideration. Select UNKNOWN when the available information does not allow these conditions to be established reliably.

This question is intended primarily to confirm the existence, currency and appropriate scope of the Explosion Risk Assessment and whether electrostatic hazards have been addressed in it. At this stage, it does not yet assess in detail which specific areas or activities those hazards relate to or whether possible electrostatic discharges can constitute an effective ignition source under the relevant process conditions. These matters are verified in subsequent audit questions.

If static electricity has been considered in the Explosion Risk Assessment and, on a documented basis, has been determined not to constitute a significant ignition source under specified conditions, that conclusion alone is not a basis for answering NO. What matters in this question is whether the issue has been properly addressed in the Explosion Risk Assessment; the validity of the conclusion reached is assessed separately later in the audit.

What to check and what evidence to expect?

1) establish which Explosion Risk Assessment (ERA) applies to the audited scope.

Check the current Explosion Protection Document (EPD) documentation and, where the ERA exists as a separate study, also review that document. Confirm the version, date and scope of the assessment. Make sure it covers the audited installation, process or area and reflects the current way the work is performed.

2) locate the records concerning ignition sources and static electricity.

ERA documentation may be structured in different ways, so do not expect one specific chapter or table. Information concerning electrostatics may be found in ignition-source analyses, risk-assessment tables, process and equipment descriptions, analyses of specific operations, or other parts of the documentation addressing hazards.

In the documentation, search for terms such as: “ignition sources”, “potential ignition sources”, “effective ignition sources”, “static electricity”, “electrostatics” and “electrostatic discharges”.

If the document is available in a searchable electronic form, use text search to locate the relevant records. For paper documentation or a scan without a text layer, review in particular the table of contents, ignition-source tables, process descriptions and assessment results.

3) check whether the scope of the assessment reflects the actual process conditions.

Confirm that the assessment relates to the current materials, equipment, installation and way the work is performed. Where start-up, shutdown, filling, emptying, cleaning, or foreseeable and rare malfunctions are relevant to the assessed scope, check that they are included within the assessment.

At this stage, do not perform your own assessment of whether a particular discharge can constitute an effective ignition source and do not assess the detailed selection of protective measures. You are checking whether the required assessment exists, is current, has the appropriate scope and addresses electrostatic hazards.

4) compare the assessment with the current state of the process and the way the work is performed.

Check whether the materials, equipment, installation, work organisation and activities performed correspond to the assumptions adopted in the ERA. Pay particular attention to changes introduced after the assessment was prepared or last updated.

If the actual way the work is performed differs from the state described in the documentation, establish whether the change was assessed and incorporated.

Expected evidence:

  • current ERA and the relevant EPD documentation;
  • records confirming that static electricity is addressed in the ignition-source assessment;
  • information confirming that the scope of the assessment reflects the current process and the relevant operating states;
  • information on changes relevant to the scope or currency of the assessment.
Answer guidance
✅ When to choose YES?✅ YES
  • a current and applicable risk assessment can be identified and its correct version can be established unambiguously.
  • the assessment covers the assessed scope and the actual current way the work is performed.
  • electrostatic hazards are addressed to an extent appropriate to the scope covered by this preliminary audit.
  • the documented assumptions can be shown to relate to the current process, materials and work organisation rather than a historical condition or a different scope.
❌ When to choose NO?❌ NO
  • it has been confirmed that the required risk assessment has not been performed.
  • the applicable assessment is outdated or does not cover the assessed scope or the current way the work is performed.
  • electrostatic hazards have not been addressed in the required assessment for the scope covered by this preliminary audit.
❓ When to choose UNKNOWN?❓ UNKNOWN
  • it cannot be established whether the required risk assessment has been performed or which version is current.
  • it cannot be established unambiguously whether the available assessment covers the assessed scope and current way of working.
  • it cannot be confirmed whether electrostatic hazards were addressed in the assessment.
  • the documentation needed to verify these elements is not available.
Answer guidance
✅ When to choose YES?
  • a current and applicable risk assessment can be identified and its correct version can be established unambiguously.
  • the assessment covers the assessed scope and the actual current way the work is performed.
  • electrostatic hazards are addressed to an extent appropriate to the scope covered by this preliminary audit.
  • the documented assumptions can be shown to relate to the current process, materials and work organisation rather than a historical condition or a different scope.
❌ When to choose NO?
  • it has been confirmed that the required risk assessment has not been performed.
  • the applicable assessment is outdated or does not cover the assessed scope or the current way the work is performed.
  • electrostatic hazards have not been addressed in the required assessment for the scope covered by this preliminary audit.
❓ When to choose UNKNOWN?
  • it cannot be established whether the required risk assessment has been performed or which version is current.
  • it cannot be established unambiguously whether the available assessment covers the assessed scope and current way of working.
  • it cannot be confirmed whether electrostatic hazards were addressed in the assessment.
  • the documentation needed to verify these elements is not available.
Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P2
Additional question

Assignment of electrostatic hazards to process areas and stages

Does the Explosion Risk Assessment (ERA) allow the specific areas, installations or process stages in which significant electrostatic hazards occur to be identified unambiguously?

Sources for confirmation:📄 Documentation👁 Observation💬 Interview
Why do we ask this?

If it is not known which areas, installations or process stages the electrostatic hazards relate to, it is not possible to determine unambiguously where further assessment should be carried out or where the relevant rules and protective measures should apply. A general statement covering the entire site may be insufficient because it does not show where the hazard is actually relevant. This may lead both to significant process areas being missed and to requirements being applied where they are not justified by the actual hazard.

Learn more

The documentation should lead to the actual location in the process

The fact that static electricity is addressed in the Explosion Risk Assessment (ERA) is only the starting point. Further assessment requires determining where in the actual process the electrostatic hazard is relevant — in which area, installation, process node or process stage.

On the basis of the ERA entry, the auditor should be able to identify in the plant the specific place, installation or process stage to which the identified hazard applies and then verify that scope in the field.

The assignment does not have to follow organisational department boundaries or use one prescribed form of presentation. It may be documented in an ERA table, an installation description, a process flow diagram, an area plan, an equipment list or several linked documents. What matters is that the assessment findings can be linked unambiguously to the actual location and the current process configuration.

Hazardous-area classification and electrostatic-hazard assignment describe different information

Hazardous-area classification identifies spaces in which an explosive atmosphere may occur with a defined frequency and duration. Assigning electrostatic hazards answers a different question: in which parts of the process do electrostatic phenomena require further assessment as a potential ignition source.

Within one Ex zone, different items of equipment and operations may have different electrostatic significance. Conversely, one process operation may involve several items of equipment, material-transfer points or parts of an installation. Hazardous-area classification and electrostatic-hazard assignment therefore serve different functions. This question does not repeat hazardous-area classification; it checks whether the ERA provides a sufficiently precise basis for identifying the parts of the process that require further assessment.

The level of detail should support further assessment

A statement such as “electrostatic hazard exists in production” or “in Ex zones” is usually too general if it does not show which installations or process stages are subject to further requirements. On the other hand, the documentation does not need a separate entry for every individual component where the scope is unambiguous and the assessment boundaries can be clearly derived.

A practically useful assignment makes it possible to identify, for example, a specific process section, filling or emptying station, material-handling node, process vessel, filtration system, transfer point or another part of the installation for which relevant activities, possible ignition sources and required protective measures can subsequently be assessed.

The importance of boundaries and interfaces between process stages

The hazard may relate not only to one item of equipment but also to a material-transfer interface between items, an interface between fixed and mobile equipment, a temporary configuration or a process state other than normal production. The assignment should therefore follow the actual material flow and operating method rather than only room or equipment names.

If the process has been modified, equipment or materials have changed, work organisation has changed or the material flow has been altered, the previous assignment may need to be reverified. An outdated hazard map may cause further assessment to be carried out for the wrong scope.

Role of this question in the audit logic

This question primarily answers “where?”. It does not yet determine in detail “during which activity?” charge is generated or accumulated, whether a possible discharge can become an effective ignition source, or which protective measures are required. Those matters are developed in subsequent stages of the audit.

What to check and what evidence to expect?

1) Start with the ERA and establish where the document locates the hazard.

Review the relevant parts of the ERA and EPD together with linked tables, lists, diagrams or plans. Using those materials, identify on a plan, diagram or directly in the plant the specific areas, installations, process nodes or process stages affected by electrostatic hazards.

Do not require one particular documentation format. What matters is whether the available material provides a clear and current scope for the subsequent assessment.

2) Go to the process and compare the documentation with the current state.

Use available process diagrams, area plans, installation drawings, process descriptions or other records showing the actual material flow and equipment. In the field, verify on a representative basis whether the areas and stages identified in the ERA exist in the documented configuration and reflect the current way the process is operated.

3) Check process boundaries and transition points.

Pay attention to material-transfer points between items of equipment, connections to mobile or temporary equipment and other process boundaries where they are relevant to the assessed scope. If start-up, shutdown, emptying, cleaning, servicing or another process state changes the assessed scope, check whether it has been appropriately included.

4) Resolve discrepancies with a person who knows the process.

If the ERA indicates a different scope from that shown by observation or current process documentation, establish the reason. Where necessary, speak with an operator, process engineer, supervisor or another person familiar with the actual process.

Boundary of the preliminary audit: at this stage, do not create your own detailed electrostatic-hazard map and do not yet determine whether a particular phenomenon can constitute an effective ignition source. The task is to check whether the applicable ERA provides a reliable and sufficiently precise basis for the subsequent audit questions.

Expected evidence:

  • current ERA and the relevant parts of the EPD;
  • tables, lists or descriptions assigning electrostatic hazards to specific areas, installations or process stages;
  • process diagrams, area plans, installation drawings, equipment lists or other documents that allow the ERA to be compared with the actual process flow;
  • observation of representative areas and process elements identified in the documentation;
  • information obtained from operators, process engineers, supervisors or other persons familiar with the process where needed to clarify the scope;
  • information on technical, material or organisational changes affecting the currency of the assignment;
  • explanation of identified discrepancies between the ERA and the actual process state.
Answer guidance
✅ When to choose YES?✅ YES

YES, if:

  • the ERA identifies specific areas, installations or process stages for which significant electrostatic hazards have been identified;
  • on the basis of the documentation, the auditor can identify in the plant the specific place, installation or process stage to which the identified hazard applies and verify that scope in the field;
  • the assignment reflects the current process flow and actual installation configuration rather than only a historical state;
  • the level of detail is sufficient to use the information in subsequent audit stages without requiring the auditor to create an independent electrostatic-hazard map.
❌ When to choose NO?❌ NO

NO when the auditor has sufficient evidence and has confirmed that:

  • the ERA addresses electrostatic hazards but does not assign them to specific areas, installations or process stages;
  • the ERA wording is so general that it is not possible to determine which parts of the process the identified hazards relate to;
  • the ERA omits a specific area, installation or process stage in which observation, documentation or other reliable information confirms the need to consider electrostatic hazards;
  • the areas, installations or process stages identified in the ERA do not correspond to the current organisation of the site or the actual process flow;
  • the scope of hazard assignment has been confirmed to be incomplete or incorrect and cannot provide an appropriate basis for further assessment.

Mere inability to verify the assignment does not mean NO; in that case the appropriate answer is UNKNOWN.

❓ When to choose UNKNOWN?❓ UNKNOWN

UNKNOWN when the available information does not allow the auditor to establish whether the hazard assignment in the ERA is correct, complete and current, in particular where:

  • the complete or current ERA is not available;
  • it cannot be confirmed which version of the documentation is current and applicable;
  • the actual process flow cannot be confirmed to the extent needed for comparison with the ERA;
  • information from documentation, observation or interviews is conflicting and the actual state cannot yet be established;
  • additional documents or information, or an interview with an operator, technologist or another person responsible for and familiar with the actual process flow, are needed;
  • the required information or the opportunity to conduct such an interview is not available at the time of assessment.

If a missing or incorrect hazard assignment has been confirmed, the appropriate answer is NO.

Answer guidance
✅ When to choose YES?

YES, if:

  • the ERA identifies specific areas, installations or process stages for which significant electrostatic hazards have been identified;
  • on the basis of the documentation, the auditor can identify in the plant the specific place, installation or process stage to which the identified hazard applies and verify that scope in the field;
  • the assignment reflects the current process flow and actual installation configuration rather than only a historical state;
  • the level of detail is sufficient to use the information in subsequent audit stages without requiring the auditor to create an independent electrostatic-hazard map.
❌ When to choose NO?

NO when the auditor has sufficient evidence and has confirmed that:

  • the ERA addresses electrostatic hazards but does not assign them to specific areas, installations or process stages;
  • the ERA wording is so general that it is not possible to determine which parts of the process the identified hazards relate to;
  • the ERA omits a specific area, installation or process stage in which observation, documentation or other reliable information confirms the need to consider electrostatic hazards;
  • the areas, installations or process stages identified in the ERA do not correspond to the current organisation of the site or the actual process flow;
  • the scope of hazard assignment has been confirmed to be incomplete or incorrect and cannot provide an appropriate basis for further assessment.

Mere inability to verify the assignment does not mean NO; in that case the appropriate answer is UNKNOWN.

❓ When to choose UNKNOWN?

UNKNOWN when the available information does not allow the auditor to establish whether the hazard assignment in the ERA is correct, complete and current, in particular where:

  • the complete or current ERA is not available;
  • it cannot be confirmed which version of the documentation is current and applicable;
  • the actual process flow cannot be confirmed to the extent needed for comparison with the ERA;
  • information from documentation, observation or interviews is conflicting and the actual state cannot yet be established;
  • additional documents or information, or an interview with an operator, technologist or another person responsible for and familiar with the actual process flow, are needed;
  • the required information or the opportunity to conduct such an interview is not available at the time of assessment.

If a missing or incorrect hazard assignment has been confirmed, the appropriate answer is NO.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P3

Consistency of documentation with the actual way the work is performed

Do the applicable work instructions, procedures or other documents governing the activities include the requirements for protection against electrostatic hazards and are they consistent with the current, actual way the work is performed?

Sources for confirmation:📄 Documentation👁 Observation💬 Interview
Why do we ask this?

Instructions and procedures translate hazard-assessment requirements into the way work is performed. They should therefore reflect the current process, materials and equipment and clearly define the rules applicable to a particular activity. If the documentation is outdated, too general or inconsistent with actual practice, a worker may perform an activity without applying the required electrostatic-protection rules. The audit therefore needs to assess both the content of the documents and their consistency with the actual way of working.

Learn more

Documentation and the actual way the work is performed

Documentation used when performing work is the practical translation of requirements arising from the risk assessment into the way specific activities are carried out. Requirements for protection against electrostatic hazards do not have to be contained in a single document or in a document with a specific title. They may be contained, among other things, in workstation and process instructions, operating procedures, process descriptions, work-preparation rules, equipment documentation, or separate requirements concerning protection against static electricity.

What matters is not so much the title of the document, but whether persons performing the activity have clear rules that are appropriate to the actual working conditions. Where the hazard assessment requires specific rules for protection against static electricity, those requirements should be translated into the documentation used during the work in a way that is understandable and practicable.

The documentation should reflect the current process, materials used, equipment, work organisation and the actual sequence of activities. The mere existence of an instruction or procedure does not by itself confirm that the applicable requirements have been effectively implemented. A document may be formally current yet still fail to reflect the actual way the work is performed or changes introduced into the process.

Differences between documentation and practice may develop gradually. They may result, among other things, from changes in equipment or materials, changes in work organisation, introduction of new ways of performing activities, operator experience, arrangements adopted after modernisation, or an established way of working that over time has begun to differ from what is described in the documentation. For this reason, consistency between documentation and actual work should be assessed not only from the document text but also against the current process.

Clarity of requirements is particularly important. General statements such as “apply static-electricity protection rules” or “provide earthing” may be insufficient if the documentation does not make clear which activity the requirement applies to, when it must be used and what method of working is required in practice.

Consistency in the way the same activity is performed by different persons and on different shifts is equally important. If the way work is performed depends primarily on the experience of a particular operator and the required rules have not been clearly defined and established in the applicable documentation, a gap may develop between the formally adopted method of work and actual operating practice.

The currency of documentation is particularly important following technical, material, process or organisational changes. A change in working conditions may mean that requirements that were previously appropriate no longer reflect the actual process. Work documentation should therefore remain linked to the current state of the process and to the results of the applicable hazard assessment.

This question assesses whether the documentation is consistent with the actual way the work is performed and whether electrostatic-hazard protection requirements have been properly translated into operating practice. It does not yet assess in detail the technical effectiveness of individual protective measures or the mechanisms of electrostatic charge generation and dissipation. Those matters are developed in subsequent audit questions.

What to check and what evidence to expect?

1) establish which documentation is actually used to perform the assessed work.

Review workstation and process instructions, procedures, process descriptions, technological records and other documents relating to the assessed activities. Do not restrict the review to documents with a particular title — electrostatic-hazard protection requirements may be distributed across several related documents.

Establish which documents are current and applicable, and whether the persons performing or supervising the work can identify the rules according to which the activity is actually carried out.

2) check whether electrostatic-hazard requirements have been translated into specific work rules.

The documentation should show which requirements apply to the assessed activity, when they must be applied and what method of working is required.

General statements such as “apply static-electricity protection rules” or “provide earthing” may be insufficient if they do not make clear what they apply to and how the worker is expected to act during the actual work.

3) compare the documentation with the actual way the work is performed.

Observe the assessed activities and check whether their actual sequence corresponds to what is described in the documentation. Compare, among other things, the materials used, equipment, sequence of activities, preparation of the work and organisation of the process.

Look for differences between the documented and actual way of working, including established practices, simplifications or other ways of performing the activity that are not described in the documentation.

4) verify the way the work is performed with persons familiar with the process.

Speak with an operator, process technologist, supervisor or another person familiar with the actual process. Establish whether the documentation reflects how the work is performed in day-to-day practice and whether the same method is followed by different operators and on different shifts.

If information obtained from documentation, observation and discussions is inconsistent, clarify the reason for the differences before giving an unequivocal answer.

5) check whether the documentation was updated after changes.

If materials, equipment, process parameters, work organisation or the way activities are performed have changed, check whether the relevant instructions, procedures and other documents were reviewed again and — where required — updated.

Pay particular attention to situations in which the actual process has changed but the documentation still describes the previous state.

Expected evidence:

  • current instructions, procedures, process descriptions or other documents applicable to the assessed activities;
  • records specifying requirements for protection against electrostatic hazards;
  • information confirming which documents are current and actually applicable;
  • observation of the actual way the work is performed;
  • information obtained from operators, process technologists, supervisors or other persons familiar with the process;
  • consistency in the way the same activity is performed by different operators or on different shifts;
  • change and update records where the process, materials, equipment or work organisation have changed;
  • information or records that allow identified discrepancies between documentation and actual practice to be explained.
Answer guidance
✅ When to choose YES?✅ YES
  • it can be established unambiguously which instructions, procedures or other documents actually apply to the assessed activities;
  • persons performing or supervising the work can identify the documents or rules under which the work is carried out;
  • the documentation contains the applicable requirements for protection against electrostatic hazards and is not limited to general safety statements;
  • the requirements are specific enough to determine which rules apply during the activity, including foreseeable non-routine situations where relevant;
  • the documentation reflects the current process, materials, equipment, work organisation and way the work is performed;
  • observation of the actual activities and interviews with an operator, technologist or another person responsible for the process confirm consistency between the documentation and practice;
  • no significant discrepancies were found between the documented and actual way of working that could affect proper application of electrostatic-protection requirements.
❌ When to choose NO?❌ NO

NO when the auditor has sufficient evidence and has confirmed that:

  • appropriate instructions, procedures or other documents defining the applicable work rules have not been provided for the assessed activities;
  • the applicable documentation does not contain the electrostatic-protection requirements that apply;
  • requirements in the appropriate documentation are confirmed to be too general or ambiguous to determine the correct way to perform the work;
  • the documentation is outdated and does not reflect the current process, materials, equipment or work organisation;
  • the actual way the activity is performed differs from the way specified in the applicable documentation;
  • confirmed shortcuts, bypasses or informal practices inconsistent with the specified rules are used;
  • different persons or shifts perform the same work according to different rules and the applicable documentation does not justify those differences.

If it cannot be established whether the auditor has the complete, appropriate and current documentation, that inability to verify alone is not a basis for NO.

❓ When to choose UNKNOWN?❓ UNKNOWN

UNKNOWN when the available evidence does not allow consistency between the documentation and the actual way the work is performed to be confirmed, in particular where:

  • not all documents that may apply to the assessed activity are available;
  • it cannot be established which document version is current and applicable;
  • the available documentation does not allow the auditor to determine whether electrostatic-protection requirements are defined in another applicable document;
  • the assessed activity could not be observed and the available information does not allow its actual performance to be reconstructed reliably;
  • explanations from an operator, technologist or another appropriate person are needed but cannot be obtained at the time of assessment;
  • information from documentation, observation or interviews is conflicting and requires further clarification.

If the auditor has the appropriate documentation and has confirmed that the requirements are incorrect, incomplete, outdated or inconsistent with actual practice, the appropriate answer is NO.

Answer guidance
✅ When to choose YES?
  • it can be established unambiguously which instructions, procedures or other documents actually apply to the assessed activities;
  • persons performing or supervising the work can identify the documents or rules under which the work is carried out;
  • the documentation contains the applicable requirements for protection against electrostatic hazards and is not limited to general safety statements;
  • the requirements are specific enough to determine which rules apply during the activity, including foreseeable non-routine situations where relevant;
  • the documentation reflects the current process, materials, equipment, work organisation and way the work is performed;
  • observation of the actual activities and interviews with an operator, technologist or another person responsible for the process confirm consistency between the documentation and practice;
  • no significant discrepancies were found between the documented and actual way of working that could affect proper application of electrostatic-protection requirements.
❌ When to choose NO?

NO when the auditor has sufficient evidence and has confirmed that:

  • appropriate instructions, procedures or other documents defining the applicable work rules have not been provided for the assessed activities;
  • the applicable documentation does not contain the electrostatic-protection requirements that apply;
  • requirements in the appropriate documentation are confirmed to be too general or ambiguous to determine the correct way to perform the work;
  • the documentation is outdated and does not reflect the current process, materials, equipment or work organisation;
  • the actual way the activity is performed differs from the way specified in the applicable documentation;
  • confirmed shortcuts, bypasses or informal practices inconsistent with the specified rules are used;
  • different persons or shifts perform the same work according to different rules and the applicable documentation does not justify those differences.

If it cannot be established whether the auditor has the complete, appropriate and current documentation, that inability to verify alone is not a basis for NO.

❓ When to choose UNKNOWN?

UNKNOWN when the available evidence does not allow consistency between the documentation and the actual way the work is performed to be confirmed, in particular where:

  • not all documents that may apply to the assessed activity are available;
  • it cannot be established which document version is current and applicable;
  • the available documentation does not allow the auditor to determine whether electrostatic-protection requirements are defined in another applicable document;
  • the assessed activity could not be observed and the available information does not allow its actual performance to be reconstructed reliably;
  • explanations from an operator, technologist or another appropriate person are needed but cannot be obtained at the time of assessment;
  • information from documentation, observation or interviews is conflicting and requires further clarification.

If the auditor has the appropriate documentation and has confirmed that the requirements are incorrect, incomplete, outdated or inconsistent with actual practice, the appropriate answer is NO.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P4

Linking electrostatic hazards to specific activities

Can the specific activities during which electrostatic charge may be generated, accumulated or discharged and which therefore require further assessment be identified unambiguously?

Sources for confirmation:📄 Documentation👁 Observation💬 Interview
Why do we ask this?

Merely stating that electrostatic hazards exist in a process is not sufficient for a proper assessment. It is necessary to know during which specific activities electrostatic charge may be generated, accumulated or discharged, because only then can the work stages requiring further analysis and the focus of subsequent audit activities be determined.

Learn more

The process activity as the location of electrostatic phenomena

Electrostatic charge is generated primarily through contact and separation of materials and in processes involving relative movement of surfaces, flow, size reduction, transfer, filtration, spraying or other mechanisms that promote charge separation. Identifying only an area or item of equipment is therefore insufficient; further assessment requires identifying the specific activities and process states during which an electrification mechanism may occur.

The actual operating sequence matters. The same material may behave differently during static storage, pneumatic conveying, transfer, container filling, filtration or installation cleaning. The same installation may also present different electrostatic conditions depending on how it is operated.

The level of detail should reflect changes in mechanism or conditions

There is no need to divide the process into every individual operator movement. It is useful, however, to distinguish operations or stages in which the material, contact and separation mechanism, flow, velocity, geometry, filling or emptying method, type of equipment or another condition relevant to charge generation, accumulation or dissipation changes.

Typical examples include liquid transfer through piping, transfer between vessels, top filling, filtration, atomisation, transfer of powders or granules, pneumatic conveying, mixing, silo discharge, filling and emptying packages, unwinding film and other operations involving intensive contact and separation of materials.

Periodic activities and states other than normal production

Electrostatic hazards may also arise during activities performed infrequently or outside the normal production cycle. Sampling, cleaning, blockage removal, removal of residual material, maintenance, process start-up and shutdown, or the use of temporary equipment may create conditions different from steady-state operation.

Where such activities are foreseeable and form part of the actual operating method, they should be included when identifying activities relevant to electrostatic hazards.

Identifying the mechanism is not yet an assessment of ignition capability

Finding that charge may be generated or accumulated during an activity does not automatically mean that an effective ignition source will occur. Relevant factors include the possible discharge type, material properties, grounding and charge-dissipation arrangements, geometry and the conditions under which an explosive atmosphere is present.

The purpose of this question is to identify correctly the activities requiring further assessment. Determining whether the identified phenomenon can lead to an effective ignition source and which protective measures are required belongs to subsequent stages of the audit.

What to check and what evidence to expect?

1) trace the actual process step by step.

Use the ERA, EPD, instructions, process flow diagrams, process descriptions and other available material. Establish the sequence of the main operations and the points at which material is moved, processed, filled, emptied, mixed, filtered, sprayed, size-reduced or otherwise exposed to conditions that may cause charge separation.

2) identify the specific activities during which electrostatic charge may be generated, accumulated or transferred.

Do not stop at general terms such as “production”, “transport” or “Ex zone”. Link the issue to a specific operation or process stage. Where several activities have different conditions or electrification mechanisms, consider them separately.

3) include foreseeable states other than normal steady operation.

Check whether start-up, shutdown, filling and emptying, sampling, cleaning, blockage removal, maintenance, periodic work or temporary equipment may be relevant. Include them where they genuinely form part of the assessed operating method and may create different electrostatic conditions.

4) verify the identification in the field and through discussion with persons familiar with the process.

Observe representative operations where they are being performed during the audit. Interview an operator, process technologist, supervisor or another person familiar with the process, particularly in relation to periodic or infrequent activities that could not be observed directly.

5) determine which activities require further assessment.

The record should make it possible to proceed unambiguously to further assessment of the significance of static electricity as a potential ignition source. At this stage, do not yet determine the ignition capability of a specific discharge or select detailed protective measures.

Expected evidence:

  • ERA, EPD, instructions, process descriptions or other documents showing the actual sequence of operations;
  • process flow diagrams, installation diagrams, process sheets or other material useful for tracing successive work stages;
  • an unambiguous list or description of activities during which significant mechanisms of electrostatic charge generation, accumulation, transfer or discharge may occur;
  • observation of representative activities in the field;
  • information obtained from operators, process technologists, supervisors or other persons familiar with the process;
  • information on periodic, non-standard activities and process states that could not be observed directly;
  • consistency between the identified activities and the current way the work is performed.
Answer guidance
✅ When to choose YES?✅ YES
  • specific activities or operations can be identified unambiguously during which electrostatic charge may be generated, accumulated or discharged;
  • those activities are linked to the relevant process stages and reflect the actual way the work is performed;
  • the identification is based on current documentation, process observation or information from persons familiar with the actual process flow;
  • the scope is specific enough to determine which activities require further assessment;
  • at this stage it is not yet necessary to decide whether a discharge can act as an effective ignition source or whether the protective measures are sufficient.
❌ When to choose NO?❌ NO

NO when the auditor has sufficient evidence and has confirmed that relevant charging mechanisms occur or are credibly possible in the assessed process, but their identification is incorrect, in particular where:

  • known charge-generation, accumulation or discharge mechanisms have not been linked to specific activities or operations;
  • the identification remains at the level of a general statement that electrostatics occurs and does not identify the actual work stages;
  • the identified activities do not reflect the current way the process is performed;
  • a specific normal, periodic, auxiliary or non-routine activity known to affect charging conditions has been omitted;
  • process observation or reliable information from persons familiar with the process confirms relevant activities that are absent from the identification;
  • the confirmed identification is so incomplete that it does not allow the activities requiring further assessment to be determined correctly.

Mere lack of information needed to establish whether a particular activity or mechanism occurs does not mean NO.

❓ When to choose UNKNOWN?❓ UNKNOWN

UNKNOWN when the auditor does not have sufficient information to determine which activities may result in generation, accumulation or discharge of electrostatic charge, in particular where:

  • the actual course of the assessed activities cannot be confirmed;
  • the assessed activity was not observed and the documentation does not allow the way it is performed to be reconstructed with sufficient accuracy;
  • it is not known whether additional periodic, auxiliary or non-routine activities relevant to charging occur;
  • an interview with an operator, technologist or another person familiar with the actual process flow is needed;
  • information from documentation, observation or interviews is incomplete or conflicting and does not allow the actual state to be established.

Key distinction: if it is known that a mechanism or activity occurs but the organisation has not identified it or has described it incorrectly, answer NO. If the auditor lacks sufficient evidence to determine whether the mechanism or activity occurs, answer UNKNOWN.

Answer guidance
✅ When to choose YES?
  • specific activities or operations can be identified unambiguously during which electrostatic charge may be generated, accumulated or discharged;
  • those activities are linked to the relevant process stages and reflect the actual way the work is performed;
  • the identification is based on current documentation, process observation or information from persons familiar with the actual process flow;
  • the scope is specific enough to determine which activities require further assessment;
  • at this stage it is not yet necessary to decide whether a discharge can act as an effective ignition source or whether the protective measures are sufficient.
❌ When to choose NO?

NO when the auditor has sufficient evidence and has confirmed that relevant charging mechanisms occur or are credibly possible in the assessed process, but their identification is incorrect, in particular where:

  • known charge-generation, accumulation or discharge mechanisms have not been linked to specific activities or operations;
  • the identification remains at the level of a general statement that electrostatics occurs and does not identify the actual work stages;
  • the identified activities do not reflect the current way the process is performed;
  • a specific normal, periodic, auxiliary or non-routine activity known to affect charging conditions has been omitted;
  • process observation or reliable information from persons familiar with the process confirms relevant activities that are absent from the identification;
  • the confirmed identification is so incomplete that it does not allow the activities requiring further assessment to be determined correctly.

Mere lack of information needed to establish whether a particular activity or mechanism occurs does not mean NO.

❓ When to choose UNKNOWN?

UNKNOWN when the auditor does not have sufficient information to determine which activities may result in generation, accumulation or discharge of electrostatic charge, in particular where:

  • the actual course of the assessed activities cannot be confirmed;
  • the assessed activity was not observed and the documentation does not allow the way it is performed to be reconstructed with sufficient accuracy;
  • it is not known whether additional periodic, auxiliary or non-routine activities relevant to charging occur;
  • an interview with an operator, technologist or another person familiar with the actual process flow is needed;
  • information from documentation, observation or interviews is incomplete or conflicting and does not allow the actual state to be established.

Key distinction: if it is known that a mechanism or activity occurs but the organisation has not identified it or has described it incorrectly, answer NO. If the auditor lacks sufficient evidence to determine whether the mechanism or activity occurs, answer UNKNOWN.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P5

Significance of static electricity as an ignition source

Do the EPD, Explosion Risk Assessment (ERA) or other documented analyses assess and resolve unambiguously whether the identified electrostatic phenomena can constitute a potential ignition source and whether such a potential source can become an effective ignition source under the actual process conditions in the assessed areas and activities?

Sources for confirmation:📄 Documentation
Why do we ask this?

The presence of static electricity or the possibility of generating and accumulating charge does not by itself mean that the phenomenon is an effective ignition source under the conditions concerned. Earlier questions establish where and during which activities charging may occur, but not every such phenomenon necessarily leads to ignition. The full scenario matters, including the possibility of charge generation and accumulation, the possible discharge type, process conditions and the ignition properties of the explosive atmosphere present, arising among other things from the type and properties of the material. Only by considering these elements together can it be assessed whether a possible discharge may constitute an effective ignition source.

In this question, verify whether the existing documentation or analysis clearly determines whether the identified electrostatic phenomena can constitute a potential ignition source and whether such a potential source can become an effective ignition source under the actual process conditions. The auditor does not repeat this specialist analysis, but verifies whether it was performed, what conclusion it reached and whether that conclusion has an appropriate documented basis.

Learn more

How do legislation and standards address ignition sources?

ATEX Directive 1999/92/EC — workplace explosion-risk assessment

The Directive on the protection of workers exposed to risks from explosive atmospheres requires the risk assessment to consider not only the likelihood and persistence of explosive atmospheres, but also the likelihood that ignition sources — including electrostatic discharges — will be present and become active and effective. Installations, substances used, processes and their possible interactions are also considered, and explosion risks are assessed overall.

This distinction is important. Merely establishing that static electricity may occur in a process does not determine whether an ignition hazard exists. The assessment should address the actual scenario in which an explosive atmosphere and an ignition source may be present at the same time under conditions capable of leading to ignition.

The same logic is reflected in Polish requirements for explosion-risk assessment, which likewise require the likelihood of ignition sources, including electrostatic discharges, to be considered together with their activation.

PN-EN 1127-1 — general methodology for explosion prevention

PN-EN 1127-1:2019-10 provides a general methodology for identifying and assessing hazardous situations that may lead to an explosion and for reducing risk. It therefore provides a broad reference for identifying ignition sources and assessing their significance in explosion safety.

In practice, ignition sources should be considered in relation to the ignition capability of the specific explosive atmosphere, rather than solely on the basis that a particular physical phenomenon is present. The possibility of that ignition source occurring under the conditions being assessed must then also be considered.

The methodology also structures ignition-source assessment according to the conditions in which a source may occur. Depending on the case, normal operation, foreseeable and rare malfunctions are considered where they are relevant to the occurrence or activation of an ignition source.

IEC TS 60079-32-1 — electrostatic hazards

IEC TS 60079-32-1:2013+A1:2017 is a detailed technical document devoted to hazards arising from static electricity. It can be used in the assessment of electrostatic hazards and describes equipment, product and process properties relevant to avoiding ignition and electrostatic shock hazards caused by static electricity.

The document covers, among other matters, earthing of conductors, reduction of charging, restriction of chargeable insulating areas, the behaviour of liquids and bulk solids, charging of people, and types of electrostatic discharge. Its purpose is to reduce the likelihood of hazardous electrostatic discharges in an explosive atmosphere to an acceptably low level.

It also illustrates why charge generation, charge retention or accumulation, the possibility of a discharge occurring, and the ignition capability of that discharge are not equivalent concepts. Different electrostatic discharge types do not necessarily have the same ignition capability.

PN-EN ISO 80079-36 — potential and effective ignition sources

PN-EN ISO 80079-36:2016-07 primarily concerns non-electrical equipment intended for explosive atmospheres and requires a formal ignition-hazard assessment. It is not a standard for carrying out the Explosion Risk Assessment of an entire workplace, but it provides a particularly useful structure for ignition-source terminology.

Within the equipment methodology used by this standard, successive levels can be distinguished:

possible ignition source → a phenomenon or type of source whose occurrence has to be considered;

potential ignition source → an equipment-related source that has the capability to ignite an explosive atmosphere;

effective ignition source → a potential ignition source considered additionally in terms of when it can occur and become effective, for example in normal operation, expected (foreseeable) malfunction or — for the relevant level of protection — rare malfunction.

This distinction is particularly important for electrostatics. Not every possibility of charging constitutes a potential ignition source, and not every potential ignition source necessarily becomes an effective ignition source in the assessed scenario.

What does this mean for electrostatic hazards?

The electrostatic-hazard assessment should determine whether, under the actual process conditions, an electrostatic discharge capable of igniting the specific explosive atmosphere can occur and whether such a scenario can realistically arise.

It is therefore not enough to state that static electricity is present or that materials, people or equipment can become charged. The assessment has to consider how charging occurs, whether a particular discharge type can arise, and the properties of the explosive atmosphere with which that discharge may come into contact.

Both the characteristics of the discharge and the properties of the material or mixture forming the explosive atmosphere are relevant. For dusts, one important parameter may be minimum ignition energy (MIE); ignition sensitivity may also be affected by particle size, moisture, composition, additives and other material properties. The data used in the analysis should therefore be representative of the material actually present in the process.

Not every possible electrostatic discharge has the same ignition capability. Different discharge mechanisms may have different significance depending on process conditions and the properties of the explosive atmosphere. The assessment should therefore not be reduced solely to the presence of charge or to a simple comparison between one energy parameter and one material value.

It is also important to determine whether a potential ignition source can become effective under the conditions concerned, meaning whether it can actually occur in a scenario in which an explosive atmosphere is present at the same time. Depending on the case, normal operation, foreseeable malfunctions and — where required — rare malfunctions may be relevant.

A properly performed analysis may therefore conclude either that a particular electrostatic phenomenon is a significant ignition source or that the scenario can be excluded on a documented basis. Excluding the hazard is not itself a deficiency; what matters is whether the conclusion has an appropriate technical basis and corresponds to the actual process conditions.

The presence of static electricity alone therefore does not establish the presence of an effective ignition source.

Boundary of the preliminary audit

As part of the preliminary audit, the auditor does not repeat a specialist ignition-source analysis, independently determine discharge energies or MIE values, or replace the appropriate technical assessment. The auditor verifies whether the appropriate analysis has been performed, whether it corresponds to the actual process conditions and whether the conclusion reached has an appropriate documented basis.

How to interpret?

This question is not intended for the auditor to perform an ignition-risk assessment independently or to determine discharge energies. It checks two related conclusions: whether the identified electrostatic phenomena have the capability to ignite the explosive atmosphere present and can constitute a potential ignition source, and whether, under the actual process conditions, such a potential source can become an effective ignition source. Select YES when both matters have been resolved unambiguously, regardless of whether the final conclusion confirms an effective ignition source or excludes it or considers it negligible on a documented basis within the assessed scope. NO means a confirmed absence of the required assessment or absence of one of the necessary conclusions. UNKNOWN means that this cannot be verified reliably.

What to check and what evidence to expect?

1) identify the document or analysis containing the conclusion.

Check the Explosion Protection Document (EPD), Explosion Risk Assessment (ERA) or another appropriate documented analysis and establish whether it applies to the assessed areas and activities. A general statement that static electricity occurs is not, by itself, an assessment of its ignition significance.

2) check the scope of the assessment performed.

Establish whether the analysis relates to the materials actually used, current process conditions, identified activities and the explosive atmosphere relevant to the assessed scope. Where foreseeable and rare malfunctions are relevant to the scenario, check whether they are included in the scope of the analysis.

3) check whether the assessment result is unambiguous.

The documentation should make clear whether the identified electrostatic phenomena can constitute a potential ignition source and whether, under the conditions considered, such a potential source can become an effective ignition source, or whether such a scenario has been excluded or considered negligible on a documented basis.

4) verify the basis for the conclusion reached.

Check the data, tests, calculations or assumptions on which the result is based. Where ignition properties of the material or explosive atmosphere are used, such as minimum ignition energy (MIE), establish whether the data relate to the material actually present and to the process conditions concerned. Relevant factors may include composition, particle size, moisture, additives, contamination or other properties affecting ignition sensitivity.

5) check whether the data and assumptions remain current.

If materials, process parameters, the way activities are performed, installation configuration or other conditions relevant to the assessment have changed since the analysis was carried out, establish whether the conclusion has been reviewed and can still be applied.

6) do not repeat the specialist analysis as part of the preliminary audit.

The auditor's task is to establish whether the appropriate assessment was performed, what its scope and result are, and whether its conclusion has an appropriate, current and documented basis. Where the available information does not allow this to be confirmed reliably, the appropriate answer is UNKNOWN and the missing data, documents or explanations should be identified.

Expected evidence:

  • the EPD, ERA or another appropriate analysis assessing whether the identified electrostatic phenomena can constitute a potential ignition source and whether, under the actual process conditions, such a source can become effective;
  • an unambiguous result of that assessment, including documented confirmation of the possibility of an effective ignition source or exclusion of or consideration of such a scenario as negligible for defined conditions;
  • the data, tests, calculations and assumptions forming the basis of the conclusion;
  • information on the properties of the material and explosive atmosphere used in the analysis, where relevant to the conclusion;
  • documentation confirming that the data and assumptions used correspond to the current materials, process conditions and activities performed;
  • records of reassessment after changes, where such changes have occurred;
  • additional specialist explanations or documents where they were needed to resolve discrepancies or uncertainties.
Answer guidance
✅ When to choose YES?✅ YES
  • an EPD, ERA or other documented analysis can be identified in which, for the relevant areas and activities, it has been assessed unambiguously whether the identified electrostatic phenomena can constitute a potential ignition source and whether, under the actual process conditions, such a source can become effective;
  • the analysis addresses both the ignition capability of the identified phenomena or possible discharges and the conditions under which a potential ignition source can become an effective ignition source;
  • the final result of the assessment is clear, whether it confirms the possibility of an effective ignition source or excludes or considers such a scenario negligible on a documented basis;
  • the conclusion relates to the actual materials, process conditions, activities performed and the explosive atmosphere relevant to the assessed scope;
  • the data and assumptions used are appropriate to current conditions and make the basis of the conclusion understandable;
  • the result is sufficiently clear to determine whether the electrostatic hazard needs to be considered in further assessment and selection of protective measures.
❌ When to choose NO?❌ NO

NO, where the auditor has the appropriate documentation and sufficient evidence and has confirmed that:

  • it has not been assessed whether the identified electrostatic phenomena can constitute a potential ignition source, or it has not been resolved whether such a source can become an effective ignition source under the actual process conditions;
  • the documentation merely states that electrostatics occur but does not resolve the ignition capability of a possible discharge or the conditions under which the source can become effective;
  • a conclusion concerning electrostatics has been adopted, but the available relevant analysis contains no basis, data or assumptions supporting that conclusion;
  • the assessment is based on outdated or non-representative data;
  • the assessment concerns a different state of the process, different materials, conditions or activities from those currently present;
  • applicable analyses contain conflicting conclusions and it has been confirmed that they have not been clarified or formally resolved.

Mere lack of access to the analysis or to the basis for the conclusion does not mean NO; where the actual state cannot be established, the appropriate answer is UNKNOWN.

❓ When to choose UNKNOWN?❓ UNKNOWN

UNKNOWN when the available information does not allow the auditor to determine whether the appropriate assessment has been performed and correctly resolves both the possibility of a potential ignition source and the possibility of it becoming an effective ignition source, in particular where:

  • it is known or there are indications that an appropriate analysis may exist but it is not available during the audit;
  • it cannot be confirmed whether the analysis made available is current, complete or applicable;
  • there is insufficient information to determine whether the data or assumptions used correspond to the current materials and process conditions;
  • it cannot be established whether the analysis resolves both the ignition capability of the identified phenomena and the conditions under which a potential ignition source can become effective;
  • it cannot be established which of several documents contains the applicable conclusion;
  • the available information is incomplete or conflicting and additional documents, data or clarification from the author of the analysis, a technologist or another appropriate person are required.

If the auditor has the appropriate analysis and confirms that the required assessment or one of the necessary conclusions is absent, answer NO. If there is insufficient evidence to establish whether such an assessment exists or is appropriate, answer UNKNOWN.

Answer guidance
✅ When to choose YES?
  • an EPD, ERA or other documented analysis can be identified in which, for the relevant areas and activities, it has been assessed unambiguously whether the identified electrostatic phenomena can constitute a potential ignition source and whether, under the actual process conditions, such a source can become effective;
  • the analysis addresses both the ignition capability of the identified phenomena or possible discharges and the conditions under which a potential ignition source can become an effective ignition source;
  • the final result of the assessment is clear, whether it confirms the possibility of an effective ignition source or excludes or considers such a scenario negligible on a documented basis;
  • the conclusion relates to the actual materials, process conditions, activities performed and the explosive atmosphere relevant to the assessed scope;
  • the data and assumptions used are appropriate to current conditions and make the basis of the conclusion understandable;
  • the result is sufficiently clear to determine whether the electrostatic hazard needs to be considered in further assessment and selection of protective measures.
❌ When to choose NO?

NO, where the auditor has the appropriate documentation and sufficient evidence and has confirmed that:

  • it has not been assessed whether the identified electrostatic phenomena can constitute a potential ignition source, or it has not been resolved whether such a source can become an effective ignition source under the actual process conditions;
  • the documentation merely states that electrostatics occur but does not resolve the ignition capability of a possible discharge or the conditions under which the source can become effective;
  • a conclusion concerning electrostatics has been adopted, but the available relevant analysis contains no basis, data or assumptions supporting that conclusion;
  • the assessment is based on outdated or non-representative data;
  • the assessment concerns a different state of the process, different materials, conditions or activities from those currently present;
  • applicable analyses contain conflicting conclusions and it has been confirmed that they have not been clarified or formally resolved.

Mere lack of access to the analysis or to the basis for the conclusion does not mean NO; where the actual state cannot be established, the appropriate answer is UNKNOWN.

❓ When to choose UNKNOWN?

UNKNOWN when the available information does not allow the auditor to determine whether the appropriate assessment has been performed and correctly resolves both the possibility of a potential ignition source and the possibility of it becoming an effective ignition source, in particular where:

  • it is known or there are indications that an appropriate analysis may exist but it is not available during the audit;
  • it cannot be confirmed whether the analysis made available is current, complete or applicable;
  • there is insufficient information to determine whether the data or assumptions used correspond to the current materials and process conditions;
  • it cannot be established whether the analysis resolves both the ignition capability of the identified phenomena and the conditions under which a potential ignition source can become effective;
  • it cannot be established which of several documents contains the applicable conclusion;
  • the available information is incomplete or conflicting and additional documents, data or clarification from the author of the analysis, a technologist or another appropriate person are required.

If the auditor has the appropriate analysis and confirms that the required assessment or one of the necessary conclusions is absent, answer NO. If there is insufficient evidence to establish whether such an assessment exists or is appropriate, answer UNKNOWN.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P6

Protective measures resulting from the identified electrostatic hazards

For the identified electrostatic hazards, have protective measures appropriate to the hazard mechanism and the actual working conditions been defined, implemented and applied?

Sources for confirmation:📄 Documentation👁 Observation💬 Interview
Why do we ask this?

Identification of a hazard alone does not reduce risk. For each significant electrostatic-hazard mechanism, protective measures appropriate to the actual materials, process conditions and way the work is performed must be specified, and their implementation and use must then be confirmed. A measure that is effective for one mechanism does not necessarily control another type of charging or discharge.

Learn more

Protective measures against electrostatic hazards

Protective measures should arise from the previously identified hazard and correspond to the particular scenario in which an electrostatic phenomenon could lead to ignition of an explosive atmosphere. There is no single universal measure that is appropriate for every process, material and type of possible discharge.

ATEX Directive 1999/92/EC requires technical and/or organisational measures appropriate to the nature of the operation, following the priority of preventing the formation of explosive atmospheres, avoiding their ignition and — where necessary — mitigating the effects of an explosion. PN-EN 1127-1:2019-10 presents explosion safety as a process of risk assessment and risk reduction using appropriate preventive and protective solutions.

The protective measure must correspond to the hazard mechanism

For static electricity, it is important to understand which part of the scenario the applied measure acts upon. A measure may reduce charging, provide safe dissipation of charge, prevent hazardous potential differences, restrict chargeable insulating surfaces, or reduce the possibility of a particular type of discharge occurring.

IEC TS 60079-32-1:2013+A1:2017 identifies, among the basic approaches to controlling static electricity, earthing of conductors, reduction of charging and restriction of chargeable areas of insulators. A solution that is appropriate for an isolated metallic item therefore need not be appropriate for an insulating surface, a flowing liquid, bulk solids, an FIBC or charging of a person.

Earthing and equipotential bonding — fundamental, but not universal

For conductive items, earthing and equipotential bonding are fundamental protective measures, but they perform different and complementary functions. Equipotential bonding limits potential differences between conductive items, while earthing provides a path for charge to dissipate to earth.

Earthing does not prevent charge from being generated and it is not a solution to every electrostatic problem. For insulating materials or other hazard mechanisms, different solutions may be required, such as reducing charging, selecting suitable materials, restricting insulating surfaces or — in appropriate applications — ionisation.

Electrostatic protection is a system

In many processes, protection depends on several elements working together. One example is charge dissipation from a person through the person–footwear–floor–earth system. Likewise, technical solutions may need to be complemented by organisational rules, the correct sequence of operations, training, monitoring or process interlocks.

The presence of one individual measure — for example an earthing conductor, footwear with specified properties or an ioniser — should therefore not automatically be equated with full control of the hazard. Effectiveness depends on the complete solution operating under the conditions for which it was intended.

Effectiveness must be maintained

A correctly selected measure can lose effectiveness over time because of wear, corrosion, contamination, damage, changes in material properties or changes to the process. Protection against electrostatic hazards therefore does not end with one-time implementation: depending on the solution, inspections, measurements, functional tests and reassessment after changes may be required.

Detailed technical criteria, measurement values and inspection frequencies should arise from the relevant assessment, technical documentation and applicable standards and guidance; a single limit value should not be treated as universal for every measure and process.

Further information in the guide

Detailed principles for earthing and equipotential bonding, transfer of liquids and bulk solids, floors, footwear and clothing, ionisation, FIBCs, inspection and measurement, operational practices and earth-monitoring systems are described in the guide “Protection against static electricity in industrial installations”.

What to check and what evidence to expect?

1) establish which protective measures arise from the assessment performed.

Check the Explosion Risk Assessment (ERA), Explosion Protection Document (EPD), technical analyses, instructions or other appropriate documents and establish which measures have been specified for the particular identified electrostatic hazards and assessed activities. It should be possible to trace the link between the identified hazard and the applied measure.

2) check whether the applied measures correspond to the hazard mechanism.

Establish what each measure is intended to prevent or limit. Depending on the hazard, measures may include earthing and equipotential bonding of conductive items, limiting charging or charge retention, appropriate selection of materials and equipment, process-operating requirements, personnel-related measures, organisational controls, monitoring, interlocks or other solutions arising from the assessment. Do not assume that one type of safeguard is appropriate for every electrostatic mechanism.

3) check whether the required measures have actually been implemented and are used.

Verify in the field that the specified solutions exist, are available and are applied in the situations for which they were intended. Pay attention to omitted safeguards, temporary arrangements, bypasses and differences between persons or shifts.

4) check whether protection depends on several elements or rules working together.

Where protection requires several measures to function together, confirm the complete required system rather than only one element. Examples include equipotential bonding together with earthing, the person–footwear–floor–earth system, a required sequence of operations, or monitoring operating together with a process interlock.

5) check whether the measures remain current and effective.

If materials, equipment, process parameters, installation configuration or the way the work is performed have changed, establish whether continued suitability of the adopted measures has been confirmed. Where the effectiveness of a measure requires periodic inspection, measurement or functional testing, check the appropriate records confirming that such verification has been carried out.

6) resolve significant discrepancies before giving an unambiguous answer.

Where documentation, observation and information from persons familiar with the process indicate different ways in which the measures are applied, establish the actual situation. The preliminary audit does not replace technical design or specialist selection of safeguards — the auditor checks whether the measures have an appropriate basis, have been implemented and function under the actual working conditions.

Expected evidence:

  • the ERA, EPD or another appropriate analysis identifying the required measures and their link to the identified hazard;
  • instructions, procedures, technical documentation or other records defining how the required measures are to be applied;
  • observation of the actual activities and the condition of the solutions applied;
  • information from operators, process engineers, supervisors or other persons familiar with the process, used to confirm how the measures are actually applied;
  • results of appropriate inspections, measurements or functional tests where these are required for the measure concerned;
  • change documentation and reassessment of the adopted solutions where process conditions have changed;
  • records or explanations sufficient to resolve identified discrepancies.
Answer guidance
✅ When to choose YES?✅ YES
  • specific protective measures arising from the identified electrostatic hazards can be indicated — technical, organisational, or an appropriate combination of both types.
  • the link between the hazard and the applied measure can be traced in the documentation or is explained unambiguously by persons responsible for the process or safety.
  • the measures correspond to the actual materials, process conditions and way the assessed activities are performed, and their scope and conditions of use are defined unambiguously.
  • the required measures have actually been implemented, are available and are applied during actual work.
  • where protection depends on several interacting elements or rules, it can be confirmed that the required elements are used together and are not replaced by solutions that do not follow from the adopted assessment.
❌ When to choose NO?❌ NO
  • no required protective measures have been defined for an identified hazard, or measures specified in the documentation have not been implemented.
  • the applied measure does not correspond to the hazard mechanism, actual materials, process conditions or way the work is performed.
  • a required measure formally exists but is unavailable, not used or bypassed while the work is performed.
  • requirements are applied selectively or differently by individual persons or shifts, without a justified basis arising from the assessment.
  • after a change in material, equipment, process parameters or way of working, it has not been verified whether the existing measures remain appropriate.
  • process observation or consistent information from persons performing the work confirms that actual practice does not ensure use of the measure under the conditions for which it is required.
❓ When to choose UNKNOWN?❓ UNKNOWN
  • the available information does not allow it to be established which protective measures arise from the identified hazard or what the basis for their selection is.
  • it cannot be confirmed whether the required measures have been implemented, are available and are applied during actual work.
  • measures are being used, but there is insufficient information to confirm that they are appropriate to the actual materials, process conditions or way the work is performed.
  • the assessed activity was not observed and the available documentation and interviews do not allow the way the required measures are applied to be confirmed reliably.
  • documentation, observations or information obtained from responsible persons is incomplete, ambiguous or conflicting and requires clarification before an unambiguous answer can be given.
◌ When to choose NOT APPLICABLE?◌ NOT APPLICABLE

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Answer guidance
✅ When to choose YES?
  • specific protective measures arising from the identified electrostatic hazards can be indicated — technical, organisational, or an appropriate combination of both types.
  • the link between the hazard and the applied measure can be traced in the documentation or is explained unambiguously by persons responsible for the process or safety.
  • the measures correspond to the actual materials, process conditions and way the assessed activities are performed, and their scope and conditions of use are defined unambiguously.
  • the required measures have actually been implemented, are available and are applied during actual work.
  • where protection depends on several interacting elements or rules, it can be confirmed that the required elements are used together and are not replaced by solutions that do not follow from the adopted assessment.
❌ When to choose NO?
  • no required protective measures have been defined for an identified hazard, or measures specified in the documentation have not been implemented.
  • the applied measure does not correspond to the hazard mechanism, actual materials, process conditions or way the work is performed.
  • a required measure formally exists but is unavailable, not used or bypassed while the work is performed.
  • requirements are applied selectively or differently by individual persons or shifts, without a justified basis arising from the assessment.
  • after a change in material, equipment, process parameters or way of working, it has not been verified whether the existing measures remain appropriate.
  • process observation or consistent information from persons performing the work confirms that actual practice does not ensure use of the measure under the conditions for which it is required.
❓ When to choose UNKNOWN?
  • the available information does not allow it to be established which protective measures arise from the identified hazard or what the basis for their selection is.
  • it cannot be confirmed whether the required measures have been implemented, are available and are applied during actual work.
  • measures are being used, but there is insufficient information to confirm that they are appropriate to the actual materials, process conditions or way the work is performed.
  • the assessed activity was not observed and the available documentation and interviews do not allow the way the required measures are applied to be confirmed reliably.
  • documentation, observations or information obtained from responsible persons is incomplete, ambiguous or conflicting and requires clarification before an unambiguous answer can be given.
◌ When to choose NOT APPLICABLE?

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P7

Instructions relating to electrostatic hazards

Are the requirements concerning electrostatic hazards contained in the applicable instructions or procedures available to persons performing the work, known to them and consistently applied during actual activities?

Sources for confirmation:📄 Documentation👁 Observation💬 Interview
Why do we ask this?

Even technically correct requirements do not provide protection if they are not available to the people who perform the work, are not understood to the required extent, or are not followed in practice. This question therefore verifies the operational implementation of the rules.

Learn more

Organisational measures for controlling electrostatic hazards

Protection against electrostatic hazards is not based solely on technical solutions. ATEX Directive 1999/92/EC explicitly requires technical and/or organisational measures appropriate to the nature of the operation. Annex II also addresses worker training and — where required by the explosion protection document — written instructions and a permit-to-work system for specified activities.

Instructions, procedures, a defined sequence of operations, work-preparation rules, supervision, training or a permit-to-work system can therefore be genuine organisational protective measures when they arise from the hazard assessment and reduce the likelihood of a hazardous scenario.

A procedure should arise from risk assessment

HSE notes that procedures are agreed safe ways of doing work, but their use should be informed by risk assessment. They should not automatically be treated as the only barrier where a more reliable technical solution can more effectively reduce the opportunity for human error. Well-designed technical and organisational measures normally complement one another.

If safety depends, for example, on connecting earthing before transfer starts, following a defined sequence or using specified equipment, that requirement should be translated into an unambiguous way of performing the work.

Procedures and competence are linked

Issuing an instruction alone does not make an organisational measure effective. HSE emphasises that procedures do not replace competence, and training alone is not sufficient evidence of competence. What matters is the combination of knowledge, skills and experience and the ability to apply the requirement correctly during actual work.

This is particularly important for infrequent activities, non-routine situations and contractor work, where local requirements may not be obvious.

Link to the guidance

The practical role of procedures, training and supervision within the protection system is developed in the guide “Protection against static electricity in industrial installations”, particularly in chapter 12 “Operational practices” and chapter 13 “Responsibilities and roles in electrostatic-hazard control”.

What to check and what evidence to expect?

1) establish which organisational protective measures apply to the assessed work.

Review instructions, procedures, work rules, permit-to-work requirements or other established requirements relating to electrostatic hazards. Determine which are current, which activities they apply to and who is covered.

2) check availability and knowledge of the requirements.

Speak with persons performing and supervising the work. Establish whether they know which rules apply to them, where the applicable requirements can be found and when they must be used. Expert knowledge is not expected — what matters is knowledge needed to perform their own work safely.

3) compare the requirements with the actual way the work is performed.

Observe the assessed activities. Look for omitted steps, shortcuts, bypasses, customary practices and differences between persons or shifts. If actual work differs from the documentation, clarify the reason before giving a definite answer.

4) include infrequent activities and non-routine situations.

Where foreseeable periodic, temporary or other non-routine activities occur, check whether appropriate rules are defined and known to the persons who may perform them.

5) include contractors and other persons involved in the work.

Where they are subject to the same protective requirements, check whether those requirements have been effectively communicated and are applied in practice.

Expected evidence:

  • current instructions, procedures, work rules, permits or other relevant documents;
  • workers can identify requirements applicable to their activities;
  • observation of the actual work;
  • consistent information from persons performing and supervising the work;
  • training, instruction or communication records where these form part of the adopted system;
  • rules for non-routine work and contractors where applicable;
  • explanation of identified differences between documentation and practice.
Answer guidance
✅ When to choose YES?✅ YES
  • current instructions, procedures or other applicable rules relating to the assessed activities and electrostatic hazards can be identified.
  • persons performing the work know which requirements apply to them and where they can find the applicable instruction or procedure.
  • the requirements are understood to the level needed to perform the work correctly, including foreseeable non-routine situations where relevant to the activity.
  • observation of actual work confirms that the requirements are applied consistently and do not exist only formally in documentation.
  • the same applicable rules are communicated effectively to contractors and other persons taking part in the assessed activities, where applicable.
❌ When to choose NO?❌ NO
  • for work requiring specific electrostatic-hazard rules, no appropriate instruction, procedure or other unambiguous means of communicating the requirements has been provided.
  • an instruction or procedure exists, but persons performing the work do not know that it applies, do not have access to it, or cannot identify the rules relating to their work.
  • requirements are applied selectively, differently between operators or shifts, or are replaced by customary practices that conflict with the applicable rules.
  • foreseeable non-routine situations requiring specified conduct are not covered by the instruction or are not known to persons performing the work.
  • observation or consistent interview evidence confirms that requirements stated in the instructions are not actually applied.
❓ When to choose UNKNOWN?❓ UNKNOWN
  • the applicable instructions or procedures are not available and it cannot be established which requirements apply to persons performing the assessed work.
  • documents are available, but it cannot be confirmed which are currently applicable or what scope and persons they cover.
  • it was not possible to interview persons performing the work or otherwise verify reliably their knowledge and application of the requirements.
  • the assessed activity was not observed and the available information does not allow practical application of the instructions to be confirmed.
  • documentation, observations or information obtained from different persons is conflicting and requires clarification before an unambiguous answer can be given.
◌ When to choose NOT APPLICABLE?◌ NOT APPLICABLE

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Answer guidance
✅ When to choose YES?
  • current instructions, procedures or other applicable rules relating to the assessed activities and electrostatic hazards can be identified.
  • persons performing the work know which requirements apply to them and where they can find the applicable instruction or procedure.
  • the requirements are understood to the level needed to perform the work correctly, including foreseeable non-routine situations where relevant to the activity.
  • observation of actual work confirms that the requirements are applied consistently and do not exist only formally in documentation.
  • the same applicable rules are communicated effectively to contractors and other persons taking part in the assessed activities, where applicable.
❌ When to choose NO?
  • for work requiring specific electrostatic-hazard rules, no appropriate instruction, procedure or other unambiguous means of communicating the requirements has been provided.
  • an instruction or procedure exists, but persons performing the work do not know that it applies, do not have access to it, or cannot identify the rules relating to their work.
  • requirements are applied selectively, differently between operators or shifts, or are replaced by customary practices that conflict with the applicable rules.
  • foreseeable non-routine situations requiring specified conduct are not covered by the instruction or are not known to persons performing the work.
  • observation or consistent interview evidence confirms that requirements stated in the instructions are not actually applied.
❓ When to choose UNKNOWN?
  • the applicable instructions or procedures are not available and it cannot be established which requirements apply to persons performing the assessed work.
  • documents are available, but it cannot be confirmed which are currently applicable or what scope and persons they cover.
  • it was not possible to interview persons performing the work or otherwise verify reliably their knowledge and application of the requirements.
  • the assessed activity was not observed and the available information does not allow practical application of the instructions to be confirmed.
  • documentation, observations or information obtained from different persons is conflicting and requires clarification before an unambiguous answer can be given.
◌ When to choose NOT APPLICABLE?

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P8

Earthing and equipotential bonding (where required by the nature of the hazard)

Where earthing or equipotential bonding is a required protective measure against electrostatic hazards, have the rules for its use been defined and are they correctly implemented in practice?

Sources for confirmation:📄 Documentation👁 Observation💬 Interview
Why do we ask this?

A conductive item electrically isolated from earth can accumulate charge and reach a potential capable of producing a spark discharge. Equipotential bonding limits potential differences between conductive items, while earthing provides a path for charge to dissipate to earth. The effectiveness of these measures depends not only on their technical construction but also on applying them to the appropriate items and operations and using them correctly during actual work. Particular attention is needed where the plant configuration changes, an item is moved or disconnected, or a connection is made before a specific operation starts.

Learn more

Earthing and equipotential bonding — different functions

In electrostatic-hazard control, earthing and equipotential bonding perform different but complementary functions. Equipotential bonding limits potential differences between conductive items, while earthing provides a path for charge to dissipate to earth. The guide notes that a connection to earth alone does not solve the problem if hazardous potential differences can still arise between conductive parts.

Electrically isolated conductive items are especially important

A conductive object that is electrically isolated from earth can accumulate charge and reach a potential capable of producing a spark discharge. IEC TS 60079-32-1 and recognised industry guidance therefore emphasise electrical continuity for conductive items that can become hazardously charged in the process concerned.

The entire conductive path matters. Coatings, corrosion, contamination, loose joints, insulating supports or configuration changes can cause an item that is assumed to be “metal and earthed” to become electrically isolated in practice.

Earthing is not a universal measure

Earthing conductive parts does not prevent charge generation itself and does not automatically control hazards associated with insulating materials, plastic surfaces, some liquids or bulk solids. Other measures may be required according to the hazard mechanism.

A single resistance criterion should not be transferred to every application. Acceptance values, the connection method and the need for monitoring should follow from the relevant technical document, the type of object and the process scenario.

The connection must be present when it is needed

For transfer operations, the presence of a conductor or clamp is not enough; the operating sequence also matters. HSE guidance on flammable liquids emphasises making required connections before flow begins and maintaining them effectively during the operation. Detailed arrangements and technical criteria are described in chapter 4 of the guide.

What to check and what evidence to expect?

1) start with the available documents and inspection results.

Check whether documents or records are available for the assessed area that allow you to establish that required earthing and equipotential bonding have been provided and are subject to inspection. These may include the explosion risk assessment, Explosion Protection Document, instructions, technical analyses, plant documentation, electrical-installation inspection reports or other relevant records.

The purpose is not to analyse every connection point or review the entire design documentation of the site. Establish primarily whether an adopted system exists, what scope it covers and whether the available information indicates significant abnormalities. Assess measurement methods, acceptance criteria and inspection frequency in detail in question 9.

2) establish where earthing or equipotential bonding matters during actual work.

Speak with a person familiar with the process and, where relevant, with persons performing the work. Establish during which activities earthing or equipotential bonding is required and whether it concerns fixed plant, mobile equipment, containers, hoses, detachable components or temporarily made connections.

3) select representative locations and operations for field inspection.

Do not attempt to inspect every connection in the facility. Select several representative or more critical examples appropriate to the assessed process.

Examples of locations and operations requiring particular attention include:

  • pipework and pneumatic conveying systems — especially flanged joints, detachable sections, flexible inserts, expansion joints, flexible hoses, and joints incorporating gaskets or plastic components;
  • bulk-solids handling systems — chutes, hoppers, transfer points, feeders, screw conveyors, conveyors, bucket elevators, screens, mills and mixers;
  • silos, vessels, cyclones, filters and dust collectors — including conductive auxiliary components, nozzles, hoses and equipment connected to the system;
  • filling and emptying stations for drums, containers, IBCs and road tankers — especially where the container or vehicle is earthed before the operation starts;
  • Type C FIBCs — where correct connection to earth forms part of the adopted protective concept during filling or emptying;
  • mobile tanks, carts, containers, drums and other process equipment — especially where movement can interrupt the charge-dissipation path;
  • conductive hoses and flexible lines — particularly where metal end fittings, helices or other conductive parts are present and electrical continuity is not obvious;
  • transfer, dosing, weighing and packing stations — including filling heads, lances, nozzles, funnels, scales, receiving containers and other conductive items involved in the operation;
  • plant components disconnected during cleaning, maintenance, repair or changeover — especially where the required connection may not be restored after reassembly;
  • temporary equipment used during repairs, sampling, emptying, cleaning or other non-routine work — for example temporary hoses, pumps, industrial vacuum cleaners, containers or transfer sets.

Pay particular attention to locations where a metal item may appear to be connected to the plant but is actually electrically isolated by a gasket, coating, contamination, flexible insert, plastic component, insulating support or the method of assembly.

4) for manually performed operations, speak with the operator.

This is particularly relevant to activities such as transferring liquids, filling and emptying containers, transferring bulk solids, handling FIBCs, sampling or using mobile equipment.

Establish:

  • what must be earthed or equipotentially bonded;
  • when the connection must be made;
  • where the clamp or lead must be connected;
  • whether the connection must be made before transfer, filling, emptying or another activity starts;
  • how long the connection must be maintained;
  • when it may be disconnected;
  • what must be done if the correct connection cannot be made or confirmed.

Do not expect design-level knowledge from the operator. The operator should, however, know the rules needed to carry out their own work safely.

5) perform a representative field inspection.

On selected examples, check whether required earthing and equipotential-bonding connections actually exist and whether the method of connection is appropriate to the nature of the installation or operation.

In particular, check for visible omissions, damage, loss of continuity, incorrect connection points or other conditions indicating that a conductive item may remain electrically isolated.

If recurring abnormalities are found in a small, appropriately selected sample, treat this as a reason to extend the scope of verification.

Expected evidence:

  • explosion risk assessment, Explosion Protection Document, technical analysis, instruction or another appropriate basis identifying the required application of earthing or equipotential bonding;
  • available inspection reports or other records confirming that earthing and equipotential bonding are subject to verification;
  • instructions or established rules for temporarily made connections, where such activities occur;
  • consistent explanations from persons performing and supervising the relevant operations;
  • representative observation of selected connections, equipment and operations in the field;
  • technical documentation, a diagram or drawing of a specific arrangement where needed to explain an observed condition or discrepancy.

A lead, clamp or statement that “everything is metal” is not sufficient evidence of correctness. A measurement report alone also does not confirm that the correct items are protected or that required connections are applied at the correct stage of the actual operation.

The detailed assessment of inspection scope, measurement methods, acceptance criteria, test frequency and handling of results is carried out in question 9.

Answer guidance
✅ When to choose YES?✅ YES
  • it can be established where earthing or equipotential bonding is required as a protective measure against electrostatic hazards.
  • available documents and inspection records confirm that these arrangements have been provided and are subject to verification.
  • for operations requiring a temporary or manually made connection, it has been defined what must be connected, where and when the connection is to be made, and how long it must be maintained.
  • persons performing such operations know the required method of work.
  • representative field inspection does not reveal significant or recurring abnormalities.
  • mobile, portable, interchangeable and temporary equipment has been included where earthing or equipotential bonding is required.
❌ When to choose NO?❌ NO
  • a required earthing or equipotential-bonding connection is confirmed to be absent.
  • a required connection is made at the wrong place or time, or is not maintained for the required duration.
  • representative inspection identifies conductive items unintentionally isolated, for example by gaskets, coatings, contamination, insulating components or the method of assembly.
  • operators do not know the required sequence of actions or follow rules different from those established.
  • required connections are omitted, disconnected before the operation is complete or replaced by improvised arrangements.
  • mobile, interchangeable or temporary equipment has not been included in the required arrangement.
  • recurring discrepancies are identified between the established rules and the actual method of work.
❓ When to choose UNKNOWN?❓ UNKNOWN
  • there is insufficient information to establish where earthing or equipotential bonding is required.
  • the relevant documents, inspection records or other evidence needed to assess the arrangements have not been made available.
  • it was not possible to perform a representative field inspection.
  • it was not possible to verify how operations are performed where earthing or equipotential bonding is relevant.
  • information from documents, discussions and observations is incomplete or conflicting and does not allow a conclusive assessment.
◌ When to choose NOT APPLICABLE?◌ NOT APPLICABLE

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Answer guidance
✅ When to choose YES?
  • it can be established where earthing or equipotential bonding is required as a protective measure against electrostatic hazards.
  • available documents and inspection records confirm that these arrangements have been provided and are subject to verification.
  • for operations requiring a temporary or manually made connection, it has been defined what must be connected, where and when the connection is to be made, and how long it must be maintained.
  • persons performing such operations know the required method of work.
  • representative field inspection does not reveal significant or recurring abnormalities.
  • mobile, portable, interchangeable and temporary equipment has been included where earthing or equipotential bonding is required.
❌ When to choose NO?
  • a required earthing or equipotential-bonding connection is confirmed to be absent.
  • a required connection is made at the wrong place or time, or is not maintained for the required duration.
  • representative inspection identifies conductive items unintentionally isolated, for example by gaskets, coatings, contamination, insulating components or the method of assembly.
  • operators do not know the required sequence of actions or follow rules different from those established.
  • required connections are omitted, disconnected before the operation is complete or replaced by improvised arrangements.
  • mobile, interchangeable or temporary equipment has not been included in the required arrangement.
  • recurring discrepancies are identified between the established rules and the actual method of work.
❓ When to choose UNKNOWN?
  • there is insufficient information to establish where earthing or equipotential bonding is required.
  • the relevant documents, inspection records or other evidence needed to assess the arrangements have not been made available.
  • it was not possible to perform a representative field inspection.
  • it was not possible to verify how operations are performed where earthing or equipotential bonding is relevant.
  • information from documents, discussions and observations is incomplete or conflicting and does not allow a conclusive assessment.
◌ When to choose NOT APPLICABLE?

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P9

Inspection, measurement and maintenance of electrostatic-protection measures (where applicable)

Are electrostatic-protection measures whose effectiveness requires periodic confirmation covered by a defined system of inspection, measurement, testing or maintenance, and can it be confirmed that these activities are carried out in accordance with the adopted requirements?

Sources for confirmation:📄 Documentation👁 Observation
Why do we ask this?

A protective measure that was effective when an installation was commissioned does not necessarily retain the same properties throughout its service life. Corrosion, contamination, wear, loosening of connections, mechanical damage, ageing of materials or changes in environmental conditions can gradually reduce its effectiveness. Not every loss of effectiveness can be detected by routine visual inspection. A connection can appear correct despite degraded electrical continuity, material properties can change over time, and a monitoring system may require a functional test to confirm that it actually detects an abnormal state. The fact that a measurement has been performed does not by itself confirm effectiveness. The result should be traceable to a specific item, the required method and the applicable acceptance criterion.

Learn more

Inspection, measurement and functional testing are not the same thing

The verification method should correspond to the function of the protective measure. In one case visual inspection and checking mechanical condition may be sufficient; in another, continuity or resistance measurement may be required; and for a monitoring system, a functional test may be needed to check the response to an actual or simulated loss of the required state.

One type of protocol or one type of measurement should therefore not be expected for every electrostatic-protection measure.

What may require periodic verification?

Depending on the adopted protection system, this may include:

  • earthing paths and equipotential connections;
  • leads, clamps and connection points used during operations;
  • conductive or dissipative hoses and other items whose electrical continuity is important;
  • earthing-monitoring systems, alarms and interlocks;
  • ionising devices;
  • floors and the person–footwear–floor system where they form part of the adopted protection;
  • other devices, materials or solutions whose properties may deteriorate during service.

Detailed assessment of personnel protection, footwear, flooring and clothing is carried out in question 12.

There is no single frequency appropriate for every measure

Do not automatically assume a “once a year” rule. For protective measures used in connection with explosion hazards, the dates of systematic reviews should be defined by the employer and stated in the Explosion Protection Document. After changes that may affect the effectiveness of protection, prompt review and verification are required.

Frequency may also follow from technical documentation, the manufacturer’s instructions, an adopted standard, the risk assessment or the nature of service. A measure exposed to frequent disconnection, corrosion, contamination or intensive wear may require more frequent inspection than a solution operating under stable conditions.

Electrical-installation inspection is not the same as full verification of electrostatic protection

Polish Building Law requires an inspection of electrical and lightning-protection installations at least once every five years, including, among other things, the condition of connections and the earthing of installations and apparatus. Such a protocol can be important audit evidence, but it does not replace all inspections of electrostatic-protection measures arising from the process, the Explosion Protection Document or the adopted protection concept.

For example, a five-year electrical-installation inspection does not automatically confirm the current condition of a clamp used to earth a drum, a conductive hose, an earthing-monitoring system or other process-related protective solutions.

Test conditions can matter

For some electrostatic properties, the result depends on the conditions under which the test is performed. Relevant factors may include humidity, temperature, surface condition and cleanliness, configuration of the tested system and the way electrodes are applied or the instrument is connected.

A preliminary auditor does not need to independently judge the correctness of a specialist measurement method, but should check whether the documentation makes it possible to establish how the test was performed and which criterion was used to evaluate the result.

A single satisfactory result does not mean permanent effectiveness

A measurement confirms the condition of a measure at a particular point in time. Where properties can deteriorate over time, systematic verification matters.

Comparing results with earlier measurements may also reveal a deteriorating trend before a limit criterion is exceeded. This does not mean trend analysis is mandatory for every measure; it should be used where it provides meaningful information.

Monitoring systems also need to be checked

A monitoring system can supervise an earthing condition or another parameter during the operation itself and indicate its loss. Where the system operates with an alarm or process interlock, periodic verification should confirm not only that the device is present but also that it performs the required function.

The absence of an alarm is not by itself evidence that the system will correctly detect a real abnormal condition.

How to interpret?

Select YES only when it can be confirmed that protective measures requiring periodic verification are covered by a defined system of inspection, measurement, testing or maintenance, and representative records confirm that these activities are carried out in accordance with the adopted requirements. If a required inspection is confirmed to be missing, overdue, performed using an inappropriate verification method, or has produced a result that does not meet requirements, select NO. If the issue is solely a lack of information needed to decide, select UNKNOWN. Select NOT APPLICABLE only when a documented assessment shows that the assessed scope contains no electrostatic-protection measures requiring periodic verification of effectiveness; state the basis in the comment.

What to check and what evidence to expect?

1) start by establishing what should be checked and how often.

Review the Explosion Protection Document and other relevant documents to establish which protective measures require periodic inspection, measurement, testing or maintenance and what intervals or frequencies have been adopted for them.

Do not assume one frequency for all measures and do not automatically expect an annual measurement of every earthing connection.

2) select a representative sample of records.

Do not analyse every protocol in the plant. Select several measures of different types, preferably associated with the assessed area or more significant operations, and check their latest required results.

Examples may include:

  • a selected earthing connection or equipotential connection;
  • a lead and clamp used during liquid transfer or solids handling;
  • a conductive hose;
  • an earthing-monitoring system or interlock;
  • another measure whose effectiveness requires periodic confirmation.

3) check whether the result actually allows the measure to be assessed.

For the selected examples establish:

  • which item or measure was checked;
  • when the inspection was performed;
  • what its scope was;
  • which method was used, where relevant;
  • which acceptance criterion applied;
  • what the result was and whether it met the requirements;
  • whether test conditions were recorded where they may affect the result;
  • whether the measuring equipment had the required verification or calibration status, where applicable.

4) link the record to the actual protective measure.

For several examples, check whether the protocol can be unambiguously related to the actual device, installation, earthing point, hose, monitoring system or other protective measure.

Pay particular attention where there are many similar points or devices and the documentation does not clearly identify which item was checked.

5) check cases following repair, change or a result that did not meet requirements.

Where the selected records include a result that did not meet requirements, damage, repair or a change that may affect effectiveness, check whether the subsequent status of the measure and the required re-verification can be confirmed.

Management of changes is assessed in question 10, while the rules for responding to abnormalities and loss of effectiveness of protective measures are assessed in question 11.

Expected evidence:

  • the Explosion Protection Document or another relevant document defining review dates for the protective measures in use;
  • a plan, schedule, register or list of inspections, measurements, tests and maintenance activities;
  • current measurement protocols, inspection records, functional-test results or service records;
  • defined methods and acceptance criteria where needed to assess the particular measure;
  • identification that links the result to a specific device, installation, point or area;
  • information on test conditions where relevant to interpretation of the result;
  • confirmation of the appropriate status of measuring equipment where required;
  • records of re-verification after repair, replacement, damage or a change that may affect effectiveness;
  • for monitoring systems, records of functional tests where such tests are required;
  • as supporting evidence, the latest periodic inspection report for the electrical and lightning-protection installation insofar as it relates to the assessed earthing arrangements.

Possession of a protocol is not sufficient evidence by itself. It should be possible to establish what was checked, whether the inspection was performed within the required interval, what the result was and whether that result can be assessed against the applicable criterion.

Answer guidance
✅ When to choose YES?✅ YES
  • it can be identified which protective measures require periodic inspection, measurement, functional testing, maintenance or another form of verification.
  • for these measures, the required frequency and, where relevant, the scope, method and acceptance criteria have been defined.
  • required inspections, measurements or tests are performed at the established intervals.
  • representative records make it possible to determine what was checked, when it was checked, what the result was and whether the adopted requirements were met.
  • where the result may be affected by test conditions or the way a measurement is performed, the information needed to interpret it is available.
  • after repair, replacement, damage or another intervention that may affect effectiveness, the required re-verification has been performed.
❌ When to choose NO?❌ NO
  • required inspections, measurements, tests or maintenance activities are not performed or are performed after the required due date.
  • the required frequency has not been defined even though the measure requires periodic verification.
  • the adopted verification method does not correspond to the function of the measure, for example visual inspection alone is used where a measurement or functional test is required.
  • no criterion has been defined for deciding whether the obtained result is acceptable.
  • records do not make it possible to determine what was checked or what the actual result was.
  • a result that does not meet requirements has been obtained, yet the measure continues to be treated as effective without the required re-verification.
  • after repair, change, damage or an event that may affect effectiveness, the required re-inspection was not performed.
❓ When to choose UNKNOWN?❓ UNKNOWN
  • it cannot be established which protective measures require periodic inspection, measurement, testing or maintenance.
  • the applicable frequency or the document from which it follows cannot be established.
  • current protocols, results or other records needed to assess whether the required inspections have been performed are not available.
  • the method or acceptance criterion cannot be established even though it is needed to interpret the result.
  • an available protocol or result cannot be unambiguously linked to a specific device, installation or protective measure.
  • the documentation is incomplete, inconsistent or contradictory and does not allow an unambiguous assessment.
◌ When to choose NOT APPLICABLE?◌ NOT APPLICABLE

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Answer guidance
✅ When to choose YES?
  • it can be identified which protective measures require periodic inspection, measurement, functional testing, maintenance or another form of verification.
  • for these measures, the required frequency and, where relevant, the scope, method and acceptance criteria have been defined.
  • required inspections, measurements or tests are performed at the established intervals.
  • representative records make it possible to determine what was checked, when it was checked, what the result was and whether the adopted requirements were met.
  • where the result may be affected by test conditions or the way a measurement is performed, the information needed to interpret it is available.
  • after repair, replacement, damage or another intervention that may affect effectiveness, the required re-verification has been performed.
❌ When to choose NO?
  • required inspections, measurements, tests or maintenance activities are not performed or are performed after the required due date.
  • the required frequency has not been defined even though the measure requires periodic verification.
  • the adopted verification method does not correspond to the function of the measure, for example visual inspection alone is used where a measurement or functional test is required.
  • no criterion has been defined for deciding whether the obtained result is acceptable.
  • records do not make it possible to determine what was checked or what the actual result was.
  • a result that does not meet requirements has been obtained, yet the measure continues to be treated as effective without the required re-verification.
  • after repair, change, damage or an event that may affect effectiveness, the required re-inspection was not performed.
❓ When to choose UNKNOWN?
  • it cannot be established which protective measures require periodic inspection, measurement, testing or maintenance.
  • the applicable frequency or the document from which it follows cannot be established.
  • current protocols, results or other records needed to assess whether the required inspections have been performed are not available.
  • the method or acceptance criterion cannot be established even though it is needed to interpret the result.
  • an available protocol or result cannot be unambiguously linked to a specific device, installation or protective measure.
  • the documentation is incomplete, inconsistent or contradictory and does not allow an unambiguous assessment.
◌ When to choose NOT APPLICABLE?

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P10

Technical, organisational and process changes and work outside normal operating scope

Before technical, organisational, material or process changes are implemented, and before work outside normal operating scope begins, is their effect on electrostatic charge generation and accumulation and on the effectiveness of the applied protective measures assessed?

Sources for confirmation:📄 Documentation💬 Interview
Why do we ask this?

A technical change can have a significant effect on electrostatic hazards. A change in material, installation geometry, flow velocity, filling or transfer method, hose, gasket, coating or another process element may alter electrostatic charge generation and accumulation and the available charge-dissipation path.

A change may also affect electrical continuity, conductive or dissipative properties, the effectiveness of earthing and equipotential bonding, monitoring systems and other previously adopted protective measures. Similar effects may occur during maintenance, cleaning, blockage removal, sampling or other work carried out in a configuration different from normal operation.

Learn more

A technical change can have a significant effect on electrostatic hazards

A change does not have to involve rebuilding the whole installation. Replacing a hose, gasket, liner, coating or a metal component with a plastic one may alter electrical continuity, the charge-dissipation path or the possibility of charge accumulation.

Process parameters can also matter: flow velocity, pneumatic-conveying rate, free-fall height, product-entry geometry, mixing speed or dosing rate. Changing these parameters may increase charge generation or accumulation and affect the effectiveness of previously adopted safeguards.

Material changes also require attention

A change in raw material, formulation, moisture, additive, packaging, FIBC type, supplier or cleaning agent may be relevant where it changes properties important to electrostatic hazards. A formally minor material change may therefore require previous assumptions to be checked again.

Work outside normal operation may create a different hazard configuration

Maintenance, cleaning, blockage removal, sampling, emergency emptying or temporary equipment can alter the installation configuration for a limited period. Temporary hoses, pumps, containers, open equipment, disconnected sections, bypasses or contractor equipment may appear. Under these conditions, both charge generation and accumulation and the available dissipation paths may change.

A temporary change is still a change

If a temporary arrangement changes material, installation configuration, process parameters or protective measures, its effect on electrostatic hazards should be assessed before use. Where relevant, the conditions for its use and restoration of the intended state should also be defined.

Management of Change (MOC)

Many sites assess changes through a Management of Change (MOC) system. The existence of an MOC form is not evidence of an adequate assessment. What matters is whether the actual change was evaluated for its effect on electrostatic charge generation, accumulation and dissipation and on the effectiveness of existing protective measures.

The assessment should lead to specific actions

If a change affects previous assumptions, it may require updates to the explosion risk assessment, explosion protection document, instructions, process parameters, earthing and equipotential bonding, monitoring, inspection scope or information provided to personnel. The assessment alone is insufficient if its conclusions are not implemented before work or operation starts.

Boundary of the preliminary audit

The auditor does not repeat the specialist technical assessment of a change. The audit checks whether the change was identified and assessed before implementation, whether appropriate competent persons performed the assessment, and whether the outcome was translated into actual protective measures and working arrangements. Where specialist analysis is needed, that requirement should arise from the change-assessment process.

What to check and what evidence to expect?

1) establish how the site identifies changes and work requiring prior assessment.

Check whether a procedure, Management of Change (MOC) system, permit to work or another established mechanism is used. Do not require the system to be formally named MOC — what matters is whether it works in practice.

2) select representative examples.

Review several recent or characteristic cases, for example a material, hose, gasket, equipment or process-parameter change, a change in filling or transfer method, maintenance, cleaning or a temporary arrangement.

3) check the technical impact before implementation.

For the selected examples, establish whether the effect on electrostatic charge generation and accumulation, charge dissipation, electrical continuity and the effectiveness of earthing, equipotential bonding and other protective measures was considered. The auditor does not repeat specialist calculations — the audit confirms that the relevant issues were assessed by competent persons.

4) check what resulted from the assessment.

Where previous assumptions were affected, confirm that required protective measures, process parameters, instructions or documentation were updated before work started and that new requirements were communicated to affected personnel.

5) pay particular attention to temporary arrangements and work outside normal operation.

Check whether safe conditions, required protective measures and, where relevant, restoration of the intended state were defined.

Expected evidence:

  • a management-of-change procedure, permit to work, assessment form or other mechanism in use;
  • records of actual changes and work;
  • an impact assessment for a specific change completed before implementation;
  • technical documentation or justification where the nature of the change required it;
  • updates to the explosion risk assessment, explosion protection document, instructions, process parameters or protective measures arising from the assessment;
  • evidence that new requirements were communicated to affected persons;
  • field observation confirming that the actual state matches the adopted arrangements.

An MOC form, permit to work or signed change record alone is not sufficient evidence if it cannot be confirmed that the actual electrostatic impact of the change was assessed and the resulting requirements were implemented.

Answer guidance
✅ When to choose YES?✅ YES
  • there is an established method for identifying changes and work that may affect electrostatic hazards.
  • the assessment is performed before the change is implemented or the work begins.
  • the assessment covers the effect on electrostatic charge generation, accumulation and dissipation and on the effectiveness of existing protective measures.
  • representative examples of actual changes or work confirm that these rules are applied in practice.
  • where a change affects previous assumptions, the required protective measures, process parameters, instructions or documentation are updated before work or operation starts.
❌ When to choose NO?❌ NO
  • a change or relevant work was carried out without prior assessment of its effect on electrostatic hazards.
  • material, equipment, installation configuration, process parameters or working method were changed without checking whether the existing protective measures remain suitable.
  • the effect of the change is considered only after implementation or after a problem occurs.
  • the assessment identified required changes to protective measures, instructions, process parameters or documentation, but these were not implemented before work began.
  • a temporary arrangement is used without assessment of its electrostatic impact or without defined conditions for safe use.
  • the management-of-change or permit-to-work system is only formal, and actual examples show that electrostatic issues are omitted.
❓ When to choose UNKNOWN?❓ UNKNOWN
  • it cannot be established how changes or work requiring prior assessment are identified and assessed.
  • records or examples are unavailable to confirm that the assessment is performed before the work starts or the change is implemented.
  • it cannot be confirmed whether electrostatic hazards are included in the management-of-change or permit-to-work system.
  • it cannot be established whether required protective measures, instructions or documentation are updated after a change.
  • documentation, interviews and observations are incomplete or conflicting and do not allow a clear conclusion.

If a change or work was confirmed to have been implemented without the required prior assessment, select NO. If the information needed to decide is missing, select UNKNOWN.

Answer guidance
✅ When to choose YES?
  • there is an established method for identifying changes and work that may affect electrostatic hazards.
  • the assessment is performed before the change is implemented or the work begins.
  • the assessment covers the effect on electrostatic charge generation, accumulation and dissipation and on the effectiveness of existing protective measures.
  • representative examples of actual changes or work confirm that these rules are applied in practice.
  • where a change affects previous assumptions, the required protective measures, process parameters, instructions or documentation are updated before work or operation starts.
❌ When to choose NO?
  • a change or relevant work was carried out without prior assessment of its effect on electrostatic hazards.
  • material, equipment, installation configuration, process parameters or working method were changed without checking whether the existing protective measures remain suitable.
  • the effect of the change is considered only after implementation or after a problem occurs.
  • the assessment identified required changes to protective measures, instructions, process parameters or documentation, but these were not implemented before work began.
  • a temporary arrangement is used without assessment of its electrostatic impact or without defined conditions for safe use.
  • the management-of-change or permit-to-work system is only formal, and actual examples show that electrostatic issues are omitted.
❓ When to choose UNKNOWN?
  • it cannot be established how changes or work requiring prior assessment are identified and assessed.
  • records or examples are unavailable to confirm that the assessment is performed before the work starts or the change is implemented.
  • it cannot be confirmed whether electrostatic hazards are included in the management-of-change or permit-to-work system.
  • it cannot be established whether required protective measures, instructions or documentation are updated after a change.
  • documentation, interviews and observations are incomplete or conflicting and do not allow a clear conclusion.

If a change or work was confirmed to have been implemented without the required prior assessment, select NO. If the information needed to decide is missing, select UNKNOWN.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P11

Response to abnormalities and loss of effectiveness of protective measures

Are rules defined and applied for responding to abnormalities related to electrostatic hazards or to loss or suspected loss of effectiveness of a required protective measure, including rules for stopping work and restarting it safely?

Sources for confirmation:📄 Documentation💬 Interview
Why do we ask this?

Loss of a protective measure can directly change the safety conditions of the process. Loss of required earthing or equipotential bonding, damage to a conductive component, failure of a monitoring system, a result outside the acceptance criterion or another deviation may mean that previous assumptions concerning safe dissipation of electrostatic charge are no longer met.

Detection of an abnormality does not by itself control the hazard. An appropriate response must be defined: stopping or not starting the process, bringing the installation to a safe state, assessing the cause and confirming that the required protective measure has regained its function before work is restarted.

Learn more

Loss of a protective measure changes the safety conditions of the process

Where the adopted protection concept relies on a particular protective measure, its absence or loss of effectiveness means that process safety can no longer rely on the previous assumptions.

Examples include failure to confirm earthing of a tanker, IBC, drum or Type C FIBC; a broken or disconnected equipotential bonding connection; damage to a cable, clamp or connection point; loss of the required electrical continuity of a hose; an earthing-monitor alarm; failure of a required interlock; a verification or measurement result outside the acceptance criterion; or damage to another protective measure.

These situations do not all require an identical response. The required action should follow from the function of the measure and the relevant hazard scenario.

An alarm or monitoring system detects a condition but does not remove its cause

A monitoring system may detect loss of a required connection and generate an alarm or interlock the process. This does not mean that the cause of the abnormality has been removed.

Resetting an alarm should not replace determining why the system failed to confirm earthing. If the cause is an unsuitable connection point, contamination, cable damage or lack of actual continuity, simply restarting the system does not restore the protective function.

The operator should know the limits of their decisions

A person performing the work does not need to diagnose the technical cause independently or carry out a specialist assessment of the effectiveness of the solution. They should, however, know when not to start or when to stop work, how to bring the activity to the required safe state, whom to notify and what must not be done until the issue has been resolved.

Technical assessment and the decision to release the process for further operation should belong to the person or function with the appropriate competence and authority under the site's organisation.

A substitute measure must not be improvised

If a required protective measure is unavailable, it should not automatically be replaced by another solution simply because it appears similar.

An additional cable, different clamp, temporary hose or manual check in place of a failed interlock should be used only where its function and conditions of use have been properly assessed. If such a solution changes the way the process is operated or the adopted protective measures, its assessment should also be linked to the change-management principles addressed in question 10.

Safe restart requires confirmation that the protective function has been restored

Removal of a visible symptom does not necessarily mean that the cause has been removed.

After repair of a cable, replacement of a clamp, correction of a monitoring-system fault or another intervention, it may be necessary to reconfirm the effectiveness of the measure. The required verification should follow from the nature of the solution.

Periodic inspections, measurements and tests are assessed in question 9. This question checks whether, following a specific abnormality, the process is prevented from restarting until the required state has been confirmed.

Events and abnormalities are also sources of information

Repeated alarms, damaged clamps, loss-of-continuity events, failed verification results or unexplained electrostatic discharges may indicate a problem wider than an individual defect.

Where the same abnormality recurs, simply restoring the process to operation each time may be insufficient. The technical, organisational or process cause and the need for further analysis should be considered.

What to check and what evidence to expect?

1) establish which abnormalities require a response.

Check whether a response is defined for loss of earthing or equipotential bonding, a monitoring alarm, damage to a protective measure, a result outside requirements or another condition that may indicate loss of the required protective function.

2) check the rules for stopping and securing the work.

Establish when work must not be started or must be stopped, whom the issue is reported to, and how the process or work area is to be brought to a safe state.

3) establish who assesses the problem and decides on further action.

Check whether it is clear who may assess the cause, approve a substitute measure or release the process for restart. The operator should know their own duties and limits of responsibility.

4) check the conditions for safe restart.

Establish whether restart takes place only after the cause has been removed or the problem properly controlled and, where required, after the effectiveness of the protective measure has been reconfirmed.

5) verify actual practice.

Speak with persons performing and supervising the work. Where alarms, damage, failed verification results or other significant events have occurred, select several examples and check what was actually done.

Expected evidence:

  • instructions, procedures or other rules defining the response to loss of a protective measure;
  • defined criteria for stopping or not starting the process;
  • rules for reporting and securing the situation;
  • identification of persons or functions responsible for assessing the problem and deciding on restart;
  • alarm, fault, failure, intervention or corrective-action records where such events have occurred;
  • confirmation that the protective measure was re-verified after the abnormality was corrected, where required;
  • consistent explanations from persons performing and supervising the work;
  • observation of the actual response where an appropriate situation occurs during the audit.

The mere presence of an alarm, interlock or instruction is not sufficient evidence. It should be established whether actual loss of the required state leads to the required response and whether work is prevented from restarting until the required protective function has been restored.

Answer guidance
✅ When to choose YES?✅ YES
  • situations requiring work to be stopped, not started or restricted have been defined.
  • the method of reporting the issue and securing the process or work area has been defined.
  • it is clear who is responsible for assessing the abnormality and deciding on further action.
  • persons performing and supervising the work know the rules relevant to their activities.
  • work is restarted only after the cause has been removed, an appropriate solution has been implemented or the required protective state has otherwise been confirmed as restored.
  • representative event examples or discussions with personnel confirm that these rules are applied in practice.
❌ When to choose NO?❌ NO
  • work may continue despite confirmed loss of a required protective measure.
  • it has not been defined when work must be stopped or must not be started.
  • it is unclear whom to notify or who is authorised to assess whether work may continue.
  • an alarm, failed result, damage or other abnormality is ignored, bypassed or deferred without appropriate assessment.
  • substitute or temporary measures are used without prior confirmation that they provide the required level of protection.
  • work is restarted without confirmation that the cause has been removed or the required protective function restored.
  • persons performing or supervising the work describe conflicting response rules, confirming that no consistent practice exists.
❓ When to choose UNKNOWN?❓ UNKNOWN
  • the applicable rules are not available and it cannot be established how a specific abnormality should be handled.
  • it cannot be established who is responsible for assessing the problem and deciding on restart.
  • it was not possible to speak with persons performing or supervising the relevant activities.
  • records or other information needed to verify the response to previous events are unavailable even though such events occurred.
  • the available information is incomplete, ambiguous or contradictory.

If the required response is confirmed to be absent or work is confirmed to continue despite loss of a protective measure, select NO. If there is insufficient information to determine which rules apply or whether they are followed, select UNKNOWN.

◌ When to choose NOT APPLICABLE?◌ NOT APPLICABLE

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Answer guidance
✅ When to choose YES?
  • situations requiring work to be stopped, not started or restricted have been defined.
  • the method of reporting the issue and securing the process or work area has been defined.
  • it is clear who is responsible for assessing the abnormality and deciding on further action.
  • persons performing and supervising the work know the rules relevant to their activities.
  • work is restarted only after the cause has been removed, an appropriate solution has been implemented or the required protective state has otherwise been confirmed as restored.
  • representative event examples or discussions with personnel confirm that these rules are applied in practice.
❌ When to choose NO?
  • work may continue despite confirmed loss of a required protective measure.
  • it has not been defined when work must be stopped or must not be started.
  • it is unclear whom to notify or who is authorised to assess whether work may continue.
  • an alarm, failed result, damage or other abnormality is ignored, bypassed or deferred without appropriate assessment.
  • substitute or temporary measures are used without prior confirmation that they provide the required level of protection.
  • work is restarted without confirmation that the cause has been removed or the required protective function restored.
  • persons performing or supervising the work describe conflicting response rules, confirming that no consistent practice exists.
❓ When to choose UNKNOWN?
  • the applicable rules are not available and it cannot be established how a specific abnormality should be handled.
  • it cannot be established who is responsible for assessing the problem and deciding on restart.
  • it was not possible to speak with persons performing or supervising the relevant activities.
  • records or other information needed to verify the response to previous events are unavailable even though such events occurred.
  • the available information is incomplete, ambiguous or contradictory.

If the required response is confirmed to be absent or work is confirmed to continue despite loss of a protective measure, select NO. If there is insufficient information to determine which rules apply or whether they are followed, select UNKNOWN.

◌ When to choose NOT APPLICABLE?

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P12

Charge dissipation from a person — footwear, flooring and clothing

In areas where a person may be a source of electrostatic discharge, are appropriate charge-dissipation measures and suitable footwear, flooring and clothing properties provided, and is the effectiveness of the adopted solutions verified?

Sources for confirmation:📄 Documentation👁 Observation💬 Interview
Why do we ask this?

While walking, moving and contacting or separating materials, electrostatic charge can be generated and accumulate on a person. If it is not effectively dissipated, the person potential can rise to a level at which an electrostatic discharge may occur. Where protection relies on footwear and flooring, the complete person–footwear–flooring–earth path is important; the properties of footwear or flooring alone do not confirm effectiveness of the complete system. Clothing performs a different function: it should have suitable properties and be used in a way that limits discharges capable of igniting an explosive atmosphere.

Learn more

Footwear and flooring form one system

Where charge is dissipated from a person through footwear and flooring, both components must provide an appropriate path to earth. Suitable footwear will not be effective on an insulating surface, and suitable flooring will not provide the intended protection if footwear electrically isolates the person from the floor. Therefore, the description “antistatic footwear” or “antistatic flooring” alone does not confirm effectiveness of the complete system.

10⁸ Ω and 10⁹ Ω do not mean the same thing

Documentation may contain limits of 10⁸ Ω and 10⁹ Ω. They arise from different requirements, test methods and applications and should not be used interchangeably. In approaches used to control electrostatic ignition hazards, a limit in the order of 100 MΩ (10⁸ Ω) is commonly encountered for a charge-dissipation path through footwear and flooring. By contrast, footwear classified as antistatic under product standards may have resistance up to 1000 MΩ (10⁹ Ω). Footwear can therefore satisfy a product-level “antistatic” requirement and still fail the criterion adopted for a specific electrostatic ignition protection system.

Before assessing a result, establish what was measured, by which method, in which configuration and against which criterion.

The test method matters

The properties of footwear alone, floor resistance to earth or point-to-point resistance, the footwear–flooring combination with a person, and charge dissipation under conditions of use can all be tested separately. Results obtained by different methods should not be compared directly merely because they are all expressed in ohms. IEC 61340-4-5 specifically addresses footwear and flooring in combination with a person.

Actual conditions can change effectiveness

The charge-dissipation path can be affected by worn or contaminated footwear, insoles and overshoes, floor contamination or repairs, mats and coverings, coatings, maintenance products and environmental conditions. An entry tester may confirm a particular path through the person and footwear to the tester electrode, but it does not automatically confirm the properties of the workplace flooring.

Protective clothing is assessed according to its electrostatic function

Clothing does not replace the person–footwear–flooring–earth charge-dissipation path. It is a separate protective element intended to limit ignition-capable discharges associated with charge on the clothing material or its components.

EN 1149-5 specifies material and design requirements for electrostatic dissipative protective clothing. Material properties may be assessed, among other methods, by surface resistance according to EN 1149-1 or by charge decay according to EN 1149-3. For example, a surface-resistance criterion may be ≤ 2.5 × 10⁹ Ω, while charge-decay assessment uses criteria such as t₅₀ < 4 s or shielding factor S > 0.2. These values relate to a different function and test method from the 10⁸ Ω criterion applied to the person-to-earth path and should not be compared directly.

The auditor should confirm the applicable requirement for the actual clothing model, how it is worn, and the relevant use and maintenance conditions. The description “antistatic clothing” alone is not sufficient evidence.

What to check and what evidence to expect?

1) establish which protection system has been adopted.

Review the explosion risk assessment, explosion protection document, instructions or another appropriate technical basis. Establish where a person may be a source of electrostatic discharge and which footwear, flooring and clothing requirements apply.

2) establish the criteria and verification methods.

Where resistance values are specified, determine whether they apply to footwear, flooring or the complete system, which test method is used, what the acceptance criterion is and which technical basis supports it. Pay particular attention to 10⁸ Ω and 10⁹ Ω; do not treat them as interchangeable.

3) review representative results and actual field conditions.

Where protection relies on the person–footwear–flooring system, review several results and the actual condition of the solution. Consider the footwear in use, flooring condition, mats and coverings, contamination, repairs, coatings and other factors that can affect the charge-dissipation path.

4) check routine controls.

Where footwear testers or other control systems are used, establish what is actually measured, which criterion is set and what happens after a failed result. Do not treat an entry-tester result as automatic confirmation of workplace-flooring properties. Detailed assessment of test frequency, measurement methods and records is performed in question 9.

5) check clothing and external personnel.

Establish the required clothing properties and confirm that the clothing actually used meets those requirements. Also verify that appropriate requirements cover contractors and other persons working in the assessed area.

Expected evidence:

  • explosion risk assessment, explosion protection document, instruction or other basis defining the required protection system;
  • technical requirements for footwear, flooring, the complete system and clothing;
  • specified test methods or documents from which the adopted criteria arise;
  • person–footwear–flooring system test results where such verification is required;
  • floor test results where flooring forms part of the charge-dissipation system;
  • footwear-tester or other routine-control records where used;
  • documentation or markings confirming the required footwear and clothing properties;
  • observation of the actual flooring condition and the way footwear and clothing are used;
  • evidence that external personnel are covered by appropriate requirements where applicable.

The description “antistatic footwear”, “antistatic flooring” or “antistatic clothing” alone is not sufficient evidence. The required properties, the appropriate verification method and consistency with the intended protective function must be established.

Answer guidance
✅ When to choose YES?✅ YES
  • the areas and activities in which electrostatic charge accumulation on a person must be limited can be identified.
  • the charge-dissipation method and the requirements for footwear and flooring have been defined.
  • where protection relies on the person–footwear–flooring–earth path, effectiveness of the complete path is assessed rather than only one component.
  • appropriate acceptance criteria and verification methods have been defined for the adopted protection system.
  • required footwear and clothing are actually used, and the condition of the flooring and conditions of use do not defeat the required protective function.
  • representative inspection or test results confirm compliance with the adopted requirements.
  • the requirements also cover contractors and other persons subject to the same hazard.
❌ When to choose NO?❌ NO
  • despite an identified hazard, an appropriate method for dissipating charge from a person has not been defined.
  • protection depends on the interaction of footwear and flooring, but only one component is checked and effectiveness of the complete system cannot be confirmed.
  • a result is assessed against a criterion applicable to a different test method or a different application.
  • required footwear or clothing is not used, or products with unconfirmed properties are used.
  • the condition of the floor, coatings, mats, contamination or other layers interrupts the required charge-dissipation path.
  • a result failing the applicable requirement has been confirmed and work continues without an appropriate solution.
  • the requirements do not cover external personnel working under the same hazard conditions.
❓ When to choose UNKNOWN?❓ UNKNOWN
  • it cannot be established which charge-dissipation system has been adopted or what its requirements are based on.
  • it is not known what the stated resistance values refer to or which test method was used.
  • current results or other evidence needed to confirm effectiveness are unavailable.
  • the required properties of the footwear, flooring or clothing in use cannot be confirmed.
  • the available results cannot be linked to the actual workplace or conditions of use.
  • documentation, measurement results, observations and information obtained from workers are incomplete or conflicting.
◌ When to choose NOT APPLICABLE?◌ NOT APPLICABLE

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Answer guidance
✅ When to choose YES?
  • the areas and activities in which electrostatic charge accumulation on a person must be limited can be identified.
  • the charge-dissipation method and the requirements for footwear and flooring have been defined.
  • where protection relies on the person–footwear–flooring–earth path, effectiveness of the complete path is assessed rather than only one component.
  • appropriate acceptance criteria and verification methods have been defined for the adopted protection system.
  • required footwear and clothing are actually used, and the condition of the flooring and conditions of use do not defeat the required protective function.
  • representative inspection or test results confirm compliance with the adopted requirements.
  • the requirements also cover contractors and other persons subject to the same hazard.
❌ When to choose NO?
  • despite an identified hazard, an appropriate method for dissipating charge from a person has not been defined.
  • protection depends on the interaction of footwear and flooring, but only one component is checked and effectiveness of the complete system cannot be confirmed.
  • a result is assessed against a criterion applicable to a different test method or a different application.
  • required footwear or clothing is not used, or products with unconfirmed properties are used.
  • the condition of the floor, coatings, mats, contamination or other layers interrupts the required charge-dissipation path.
  • a result failing the applicable requirement has been confirmed and work continues without an appropriate solution.
  • the requirements do not cover external personnel working under the same hazard conditions.
❓ When to choose UNKNOWN?
  • it cannot be established which charge-dissipation system has been adopted or what its requirements are based on.
  • it is not known what the stated resistance values refer to or which test method was used.
  • current results or other evidence needed to confirm effectiveness are unavailable.
  • the required properties of the footwear, flooring or clothing in use cannot be confirmed.
  • the available results cannot be linked to the actual workplace or conditions of use.
  • documentation, measurement results, observations and information obtained from workers are incomplete or conflicting.
◌ When to choose NOT APPLICABLE?

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P13

Operational knowledge of persons performing the work

Do persons performing the work understand the electrostatic hazards associated with their activities, the function of the required protective measures, and the conditions necessary to maintain their effectiveness?

Sources for confirmation:💬 Interview
Why do we ask this?

The effectiveness of some electrostatic protective measures depends not only on correct design but also on maintaining specified conditions during operation. This includes required electrical continuity, earthing and equipotential bonding, electrostatic properties of equipment and materials, process parameters and conditions for charge dissipation. A person performing the work is not expected to know the design calculations, but should know which requirements are relevant to the activity, when they apply and which deviations invalidate the adopted safety conditions.

Learn more

Operational knowledge does not mean expert knowledge

ESH-01 is a preliminary audit. Persons performing the work should not be expected to calculate discharge energy, determine minimum ignition energy, classify discharge types or perform a specialist ignition-source assessment. The required level of knowledge should correspond to the person’s actual tasks and responsibilities.

Understanding operating conditions matters more than definitions

A person should know which stages of the activity are subject to electrostatic requirements, which measures and conditions must be provided before and during the work, what their function depends on, and which items of equipment, materials, parameters or configurations must not be changed arbitrarily. The important point is recognising the boundary beyond which the existing safe-working assumptions can no longer be relied upon.

Knowledge should include foreseeable deviations

Particular attention should be paid to infrequent activities, restart, cleaning, maintenance, changes of material or equipment and other foreseeable departures from normal operation. Question 13 checks whether the person recognises the limits of normal operating conditions. The formal management of change system is assessed in question 10, while response to loss of a required protective function is assessed in question 11.

Training records are supporting evidence

Legislation requires appropriate training in explosion protection, but a record of attendance does not by itself confirm practical understanding. The most useful verification is a short discussion linked to the actual operation, compared with the documentation and the observed way of working.

What to check and what evidence to expect?

1) Select representative activities and persons.

Do not examine the entire workforce. Select several activities relevant to electrostatic hazards and speak with persons who actually perform them. Where work differs between shifts, functions or contractors, reflect this in the sample.

2) Relate the discussion to the actual operation.

Establish whether the person can identify which electrostatic-hazard conditions must be met before and during the activity and which equipment, materials, parameters or configurations are relevant to maintaining the required protective conditions.

3) Check understanding of the function of protective measures.

The person should understand the significance of the measure to a level appropriate to their duties and know the conditions on which its correct operation depends. Do not require knowledge of design principles, calculations or technical values where these are outside the person’s responsibilities.

4) Check the limits of normal operation.

Establish whether the person recognises a situation in which a material, equipment item, configuration, process parameter or condition of a protective measure has changed in a way that requires further assessment or reporting. Detailed response rules are assessed in question 11.

5) Compare answers with documentation and observation.

Explanations should be consistent with the Explosion Risk Assessment, Explosion Protection Document, instructions and the actual way the work is carried out. Differences in wording are not important; material differences concerning the conditions or function of a protective measure are.

6) Treat training documentation as supporting evidence.

Check the scope of training or instruction and its relationship to actual tasks. A certificate or attendance list alone should not determine a YES answer.

Expected evidence:

  • practical and technically correct explanations from persons actually performing the work;
  • correct identification of the conditions applicable to the assessed activity;
  • understanding of the function of required protective measures to a level appropriate to the person’s duties;
  • recognition of significant deviations from normal operating conditions;
  • consistency of answers with documentation and observed practice;
  • broad consistency of knowledge among persons performing comparable activities;
  • training programmes, instruction records and other preparation records as supporting evidence;
  • appropriate preparation of contractors where they perform the assessed activities.

The auditor does not assess knowledge of definitions or expert-level electrostatics. The assessment is whether the person understands the requirements relevant to their own work sufficiently to apply protective measures correctly and recognise when the conditions for which they were adopted are no longer maintained.

Answer guidance
✅ When to choose YES?✅ YES
  • persons performing the assessed activities can relate electrostatic hazards to the actual way their work is carried out.
  • they know which protective measures or rules apply to their activities and in which situations they are required.
  • they understand the function of those measures to a level appropriate to their duties, without being expected to use expert terminology.
  • they know which conditions must be maintained for the adopted protective approach to remain effective.
  • they can recognise a change or deviation for which the previous safe-working assumptions cannot be relied upon without further assessment.
  • answers from persons performing comparable activities are broadly consistent with the applicable requirements and observed practice.
  • appropriate preparation can also be confirmed for contractors where they perform activities included in the assessment.
❌ When to choose NO?❌ NO
  • persons performing the work cannot relate electrostatic hazards to their own activities.
  • they do not know when a specified protective measure is required or which conditions must be maintained during its use.
  • they apply a measure only as routine but do not understand it sufficiently to recognise inappropriate conditions of use.
  • they do not recognise changes or deviations that may invalidate the adopted protective conditions.
  • they provide information that is technically inconsistent with the applicable requirements or the actual way the work is performed.
  • confirmed material differences exist in the knowledge of persons performing the same activities.
❓ When to choose UNKNOWN?❓ UNKNOWN
  • it was not possible to speak with persons actually performing the assessed activities.
  • only training records are available, without the possibility of verifying knowledge against actual work.
  • the discussion performed or the number of persons checked is insufficient for a reliable assessment.
  • the information obtained is incomplete or conflicting and the actual level of knowledge cannot be established.
◌ When to choose NOT APPLICABLE?◌ NOT APPLICABLE

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Answer guidance
✅ When to choose YES?
  • persons performing the assessed activities can relate electrostatic hazards to the actual way their work is carried out.
  • they know which protective measures or rules apply to their activities and in which situations they are required.
  • they understand the function of those measures to a level appropriate to their duties, without being expected to use expert terminology.
  • they know which conditions must be maintained for the adopted protective approach to remain effective.
  • they can recognise a change or deviation for which the previous safe-working assumptions cannot be relied upon without further assessment.
  • answers from persons performing comparable activities are broadly consistent with the applicable requirements and observed practice.
  • appropriate preparation can also be confirmed for contractors where they perform activities included in the assessment.
❌ When to choose NO?
  • persons performing the work cannot relate electrostatic hazards to their own activities.
  • they do not know when a specified protective measure is required or which conditions must be maintained during its use.
  • they apply a measure only as routine but do not understand it sufficiently to recognise inappropriate conditions of use.
  • they do not recognise changes or deviations that may invalidate the adopted protective conditions.
  • they provide information that is technically inconsistent with the applicable requirements or the actual way the work is performed.
  • confirmed material differences exist in the knowledge of persons performing the same activities.
❓ When to choose UNKNOWN?
  • it was not possible to speak with persons actually performing the assessed activities.
  • only training records are available, without the possibility of verifying knowledge against actual work.
  • the discussion performed or the number of persons checked is insufficient for a reliable assessment.
  • the information obtained is incomplete or conflicting and the actual level of knowledge cannot be established.
◌ When to choose NOT APPLICABLE?

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.
P14

Corrective actions and closure of identified nonconformities

Are identified nonconformities relating to electrostatic hazards recorded, assessed, assigned appropriate actions and responsibilities, and, after they have been corrected, is the effectiveness of the implemented solution confirmed?

Sources for confirmation:📄 Documentation👁 Observation💬 Interview
Why do we ask this?

Detecting a nonconformity does not mean that the problem has been resolved. A failed measurement, loss of electrical continuity, damage to a protective measure, an alarm from a monitoring system or another deviation should lead to assessment and appropriate action. Where the nonconformity affected the function of a protective measure, repair alone may not be sufficient; depending on the solution, an inspection, functional test, measurement or other verification may be needed to confirm that the required condition has been restored. Clear responsibility and recognition of recurring problems are also important.

Learn more

Immediate response and closure of the problem are different stages

After a nonconformity is identified, work may need to be stopped or not restarted, the installation made safe and the problem reported. This question assesses the subsequent stage: detection → recording → assessment → action → responsibility → implementation → effectiveness verification → closure.

Effectiveness verification should match the function that was lost

Not every nonconformity requires a measurement. Appropriate evidence may be a resistance or continuity measurement, a functional test of monitoring or an interlock, technical inspection of a repaired component, repetition of a previously failed test, or verification of the actual work practice. The method should correspond to the function affected by the nonconformity.

Not every fault requires a formal root-cause analysis

The depth of assessment should be proportionate to the problem. A single fault may require a straightforward technical action and verification. However, recurring damage, alarms or failed results should prompt consideration of a broader technical, operational or organisational cause.

Temporary solutions require control

A temporary measure should be clearly identified as temporary, have defined conditions of use and remain controlled until a permanent solution is implemented. If it changes the process configuration or the way a protective measure functions, it should be appropriately assessed before continued use.

What to check and what evidence to expect?

1) select representative nonconformities.

Do not review every site report. Select several cases such as a failed measurement or inspection, loss of electrical continuity, damage to an earthing or equipotential bonding component, an alarm from a monitoring system, or a deviation identified during an inspection or audit.

2) trace the handling from detection to closure.

Establish: how the problem was detected → where it was recorded → how it was assessed → what action was defined → who was responsible → what was completed → how effectiveness was confirmed → on what basis the issue was closed. A separate form for each stage is not required; the important point is whether the sequence can be confirmed reliably.

3) check the basis for closure.

Where the nonconformity concerned the function of a protective measure, establish whether the post-action verification was appropriate to that function. A status such as “repaired” or “completed” does not always confirm restoration of the required condition.

4) check recurring problems.

Establish whether similar nonconformities occurred previously and whether recurrence was recognised and appropriately assessed. The auditor does not need to perform the root-cause analysis personally.

5) check temporary solutions.

Where they exist, establish why they were introduced, the conditions under which they may be used, who is responsible for their control, and what further action has been defined.

Expected evidence:

  • nonconformity, alarm and fault reports;
  • inspection, test and measurement reports;
  • maintenance work orders or repair records;
  • assignment of actions and responsibility;
  • records confirming completion of actions;
  • post-action inspection, test or measurement results where required;
  • records for temporary solutions;
  • information allowing recurring problems to be identified;
  • evidence showing the basis on which a nonconformity was considered closed.

A separate process dedicated only to electrostatic hazards is not required. An existing technical reporting, maintenance, corrective-action or nonconformity-management system may be used if it allows the issue to be traced through to confirmation of the effectiveness of the implemented solution.

Answer guidance
✅ When to choose YES?✅ YES
  • significant nonconformities relating to electrostatic hazards are recorded or otherwise documented unambiguously;
  • the identified problem is assessed to a level appropriate to its nature and significance;
  • the required action and the person or function responsible for its completion are defined;
  • implementation of the action can be traced from reporting through to completion;
  • where the problem concerned the function of a protective measure, restoration of the required condition is confirmed by an appropriate method after repair or other action;
  • temporary solutions remain controlled and do not become permanent without appropriate assessment;
  • recurring or similar problems are recognised and, where necessary, lead to broader assessment;
  • representative examples of previous nonconformities confirm that the established process operates in practice.
❌ When to choose NO?❌ NO
  • confirmed nonconformities are not recorded or their subsequent handling cannot be traced;
  • a problem was identified but no action or responsibility for completing it was defined;
  • failed inspection, measurement or test results, or alarms, are recorded but do not lead to appropriate action;
  • an issue is treated as closed after repair alone even though the nature of the protective measure requires confirmation that its function has been restored;
  • temporary solutions or bypasses remain in service without appropriate assessment and a decision on the permanent solution;
  • the same or similar nonconformities recur and previous actions have not produced an effective solution;
  • a nonconformity was formally closed despite the absence of required evidence that the implemented solution is effective.
❓ When to choose UNKNOWN?❓ UNKNOWN
  • it cannot be established how identified nonconformities are recorded and managed;
  • representative examples of previous nonconformities are not available;
  • it is known that an action was taken, but it cannot be established whether its effectiveness was verified;
  • it cannot be established who was responsible for the action or on what basis the problem was considered resolved;
  • available records are incomplete or information from documents and interviews is contradictory.
◌ When to choose NOT APPLICABLE?◌ NOT APPLICABLE

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Answer guidance
✅ When to choose YES?
  • significant nonconformities relating to electrostatic hazards are recorded or otherwise documented unambiguously;
  • the identified problem is assessed to a level appropriate to its nature and significance;
  • the required action and the person or function responsible for its completion are defined;
  • implementation of the action can be traced from reporting through to completion;
  • where the problem concerned the function of a protective measure, restoration of the required condition is confirmed by an appropriate method after repair or other action;
  • temporary solutions remain controlled and do not become permanent without appropriate assessment;
  • recurring or similar problems are recognised and, where necessary, lead to broader assessment;
  • representative examples of previous nonconformities confirm that the established process operates in practice.
❌ When to choose NO?
  • confirmed nonconformities are not recorded or their subsequent handling cannot be traced;
  • a problem was identified but no action or responsibility for completing it was defined;
  • failed inspection, measurement or test results, or alarms, are recorded but do not lead to appropriate action;
  • an issue is treated as closed after repair alone even though the nature of the protective measure requires confirmation that its function has been restored;
  • temporary solutions or bypasses remain in service without appropriate assessment and a decision on the permanent solution;
  • the same or similar nonconformities recur and previous actions have not produced an effective solution;
  • a nonconformity was formally closed despite the absence of required evidence that the implemented solution is effective.
❓ When to choose UNKNOWN?
  • it cannot be established how identified nonconformities are recorded and managed;
  • representative examples of previous nonconformities are not available;
  • it is known that an action was taken, but it cannot be established whether its effectiveness was verified;
  • it cannot be established who was responsible for the action or on what basis the problem was considered resolved;
  • available records are incomplete or information from documents and interviews is contradictory.
◌ When to choose NOT APPLICABLE?

Choose NOT APPLICABLE when the question genuinely does not apply to the assessed scope or configuration. Justify the choice with a comment or supporting documentation.

Your answer
Add comment or documentation
Documentation / evidencemax. 5 files of each type · up to 128 MB each
📷 Photos0 / 5
You can take a photo directly in the audit or choose saved files.
📎 Documents0 / 5
Supported formats include PDF, Word, Excel, PowerPoint, OpenDocument, TXT and CSV.
The maximum file size depends on the WordPress server settings.

Automatic summary

Audit saved

Reason for further verification

This finding is a significant reason for further verification and, depending on the nature of the issue, may justify specialist analysis. You may finish the audit at this point or continue in order to collect a more complete picture of the situation.